Input voltage (V): 3 x 380 / 3 x 400 / 3 x 415 V (3F + N)
Output voltage (V): 3 x 380 / 3 x 400 / 3 x 415 V (3F + N)
Power (VA): 30000
Type: UPS Standard
Code: 681RB000003
Specifications
Technical specifications
TECHNOLOGY
On-line, double conversion, HF, DSP control
INPUT
Voltage
3 x 380 / 3 x 400 / 3 x 415 V (3F + N)
Voltage range
+15% / -20% (configurable)
Rated frequency
50 / 60 Hz
Total harmonic distortion (THDi)
100% load: <1.5% / 50% load: <2.5% / 10% load: <6.0%
Power factor
1 from 10% load
Rectifier topology
Three-phase IGBT full wave, soft start, PFC, transformerless
Input limit for peak shaving
Adjustable between 10%-100% of the power required for the output load
OUTPUT
Power factor
0,9(2)
Voltage
3 x 380 / 3 x 400 / 3 x 415 V (3F + N)
Dynamic accuracy
± 2% dynamic
Static accuracy
± 1% steady
Response time accuracy
20 ms for load steps 0% ÷ 100% and voltage drop up to -5%
Power (VA/W)
30000 / 27000
Total harmonic distortion (THDv) Linerar load
<0.5%
Total harmonic distortion (THDv) Non~linear load
<1.5% (EN-62040-3)
Synchronised frequency
50/60 Hz ±5 Hz (selectable)
Frequency
50/60 Hz +/- 5 Hz (selectable)
Frequency accuracy (battery mode)
50/60 Hz ±0.05%
Synchronous speed
From 1 Hz/s to 10 Hz/s (programmable)
Total performance in On-line mode
7.5÷60 kVA: 92.0%÷93.0% / 80÷200 kVA: 94.0%÷95.0%
Admissible overloads
125% for 10 min / 150% for 60 s / >150% for 20ms
Crest factor
3,2 a 1
MANUAL BYPASS
Protections
No breaks
STATIC BYPASS
Type and activation criteria
Solid state, controlled by microprocessor
Transfer times in On-line
Nil
Transfer to bypass
Immediate, for overloads exceeding 150%
Retransfer
Automatic, after alarm deactivation
Peak Shaving
User configurable activation
BATTERY
Battery type
Lead acid, sealed, maintenance free
Charging voltage regulation
Batt-Watch
Peak shaving function
Sizing for energy storage and supplying the load’s peaks in demand
COMMUNICATION
Ports
1 x RS232/RS485 + 1xUSB,with Modbus protocol
Relay interface
4 x AC failure, bypass, low battery and general
Intelligent slot
1, for SNMP
Monitoring software
Viewpower / UPSMAN
Backlit LCD display
LCD display, LEDs and keyboard
GENERAL
Operating temperature
0º C ÷ +40º C
Relative humidity
Up to 95%, non-condensing
Maxium operating altitude
2.400 m.s.n.m. (3)
Acoustic noise at 1 metre
<52 dB(A)(4)
IMPLEMENTATIONS
Nº Cabinets (Ups + BAT)
1 + 0
STANDARDS
Safety
EN-IEC 62040-1
Electromagnetic compatibility (EMC)
EN-62040-2
Operation
VFI-SS-11 (EN-62040-3)
Corporate cerification
ISO 9001, ISO 14001, ISO 45001
DIMENSIONS
Depth (mm)
770
Width (mm)
450
Height (mm)
1100
WEIGHT
Weight (kg)
378
(1) Up to 100 kVA. (2) Only for three-phase input/output models. PF=0.8 for all other configurations. (3) Power degradation for higher altitudes up to a maximum of 5,000 masl. (4) <65 dB(A) for 80 to 120 kVA models / <70 dB(A) for 160 to 200 kVA models.
View distributor
Region
Select Region and Country/Province to view Distributors
Downloads
Documents
Data sheet
Data Sheet SLC CUBE3+ PS
Catalogues
General Catalogue
Manuals
Manual SLC CUBE3+ PS
Certificates & Declarations
ISO 45001 certificate
ISO 9001 certificate
ISO 14001 certificate
Instructions
Safety instructions
Software
VIEWPOWER HTML
Windows
Windows
installViewPower_Windows - 109MB Download
Mac OS
Mac OS
ViewPowerHTML_MAC_x64_Intel. - 81.7MB Download
installViewPowerHTML_MAC_x64_Mchip - 79.1MB Download
Linux
Linux
ViewPowerHTML_Linux_x86_64 - 77MB Download
ViewPowerHTML_Linux_text_x86_64 - 116 MB Download
ViewPowerHTML_Linux_text_i386 - 77,9MB Download
ViewPowerHTML_Linux_i386 -77.3MB Download
Windows
Windows
ViewpowerHTML5 user's manual Download
Mac OS
Mac OS
ViewpowerHTML5 user's manual Download
Linux
Linux
ViewpowerHTML5 user's manual Download
Software questions about SLC-30-CUBE3+ PS 62AB360?
Request information about SLC-30-CUBE3+ PS 62AB360

To contact Salicru directly or request information about any of our products, please fill in the following details and press send.

Please enter your name
Please indicate the position
Please indicate the position
Please enter your email
Please enter your address
Please enter your post code
Please enter your town/city
Please enter your country
Please enter your enquiryRequired field
INFORMATION ON DATA PROTECTION OF SALICRU S.A.

Purposes: To send you information about our products, including by electronic means.

Legitimacy: Consent of the interested party. Recipients: No transfers of data to third parties are anticipated, except in the event of legal requirement.

Rights: You can withdraw your consent at any time, and exercise your rights of data access, rectification, erasure and other rights at rgpd@salicru.com, as explained in the Privacy Policy.

Additional information: You can find additional information by clicking on Legal Notice.

I wish to receive commercial information, including by electronic means.
   
Indicate if you want to receive the newsletter
Please read and accept the privacy policy
* Required field.
Barcelona Web Design: MontawebMONTAWEB.com
Welcome to Salicru. Select country/language
Algeria   Français
Angola   Português
Bahrain   English
Congo   Français
Côte d'Ivoire   Français
Egypt   English
Equatorial Guinea   Español   Português   Français
Iraq   English
Jordan   English
Kenya   English
Kuwait   English
Lebanon   English
Libya   English
Madagascar   Français
Mali   Français
Mauritania   Français
Morocco   Français
Niger   Français
Nigeria   English
Oman   English
Qatar   English
Reunion   Français
Saudi Arabia   English
Senegal   Français
South Africa   English
Syria   English
Tanzania   Français
Tunisia   Français   English
Turkey   English
Uganda   English
United Arab Emirates   English
extralarge
large
tablet
mobile
We use proprietary and third-party cookies to keep track of how our website is used and to be able to improve it, adapt the content to your tastes and personalise our advertising, marketing and social media posts. Click on the corresponding buttons to accept all of them, reject them or configure your settings. Please see our Cookie Policy for more information.