SLC TWIN PRO2 4-20 kVA
Salicru's SLC TWIN PRO2 series UPS systems feature on-line double conversion technology, currently the most advanced for the protection of critical systems as it provides a fully stabilised and filtered sinusoidal supply voltage. The systems come in a tower format and are available in power ratings of 4, 5, 6, 8, 10, 15 and 20 kVA.
The Salicru SLC TWIN PRO2's output voltage is always single-phase, featuring a single-phase input of 4 to 20 kVA and a three-phase input of 8 to 20 kVA. All devices with single-phase input provide a unitary output power factor (1), the most optimum for systems and environments with high energy needs. Adaptability is another important feature thanks to the numerous operating modes available: On-line, Batteries, Eco-mode, Bypass, Frequency converter and Parallel redundant.
The possibilities of control and monitoring are varied: on the one hand, an LCD display + keypad for local operation of the device, and, on the other, various communication options (USB HID and RS-232 interfaces, and slot for SNMP, RS-485 and AS-400 cards) that enable the UPS to be integrated into standard or virtualised platforms for management, incident notification and remote maintenance.
(1) Except 15 and 20 kVA I / I models
Maximum continuity protection for sensitive and critical systems
SALICRU's SLC TWIN PRO2 series is the best option for providing a secure power supply to ERP systems, Business Intelligence, CRM solutions, intranets/extranets and corporate networks in the event of a wide range of possible disturbances (micro power outages, voltage fluctuations, frequency variations, harmonics, transients, etc.), which can cause irreparable damage or incur high costs in all of these critical systems.
Double voltage conversion (AC/DC + DC/AC), providing the best degree of safety to loads.
For processes that require longer autonomy, this UPS allows more back-up time by additional battery modules.
A configuration of several UPS of the same capacity connected in parallel to a common output bus is possible to prevent any failure in one of the UPS from stopping the loads.
A communications port that allows the UPS to be integrated in a computer network for remote management and monitoring.
The backlit LCD panel with elegant white LED light displays all of the information regarding the UPS system’s status, such as operating mode, charging status and battery levels, alerts, etc. With its four LED indicator lights located above the screen and its audible alarm, the SLC TWIN PRO2ensures users are kept well-informed at all times.
- USB interface.
- RS-232 interface.
- Emergency stop (EPO).
- Intelligent slot for SNMP / AS400 / RS485-Modbus.
- Manual Bypass.
- Input protector.
- Terminal cover.
- Thermal rearmable input.
- Socket IEC output.
- Parallel ports.
- Earth connection.