SLC-20-CUBE3+ PS 62AB356
SLC-20-CUBE3+ PS 62AB356
Uninterruptible Power Systems three-phase from 20 kVA Peak Shaving
Energy efficiency and reduced consumption peaks
Input voltage (V):
3 x 380 / 3 x 400 / 3 x 415 V (3F + N)
Output voltage (V):
3 x 380 / 3 x 400 / 3 x 415 V (3F + N)
Power (VA):
20000
Type:
UPS Standard
Code: 681RA000011
Specifications
Technical specifications
TECHNOLOGY
On-line, double conversion, HF, DSP control
INPUT
Voltage
3 x 380 / 3 x 400 / 3 x 415 V (3F + N)
Voltage range
+15% / -20% (configurable)
Rated frequency
50 / 60 Hz
Total harmonic distortion (THDi)
100% load: <1.5% / 50% load: <2.5% / 10% load: <6.0%
Power factor
1 from 10% load
Rectifier topology
Three-phase IGBT full wave, soft start, PFC, transformerless
Input limit for peak shaving
Adjustable between 10%-100% of the power required for the output load
OUTPUT
Power factor
0,9(2)
Voltage
3 x 380 / 3 x 400 / 3 x 415 V (3F + N)
Dynamic accuracy
± 2% dynamic
Static accuracy
± 1% steady
Response time accuracy
20 ms for load steps 0% ÷ 100% and voltage drop up to -5%
Power (VA/W)
20000 / 18000
Total harmonic distortion (THDv) Linerar load
<0.5%
Total harmonic distortion (THDv) Non~linear load
<1.5% (EN-62040-3)
Synchronised frequency
50/60 Hz ±5 Hz (selectable)
Frequency
50/60 Hz +/- 5 Hz (selectable)
Frequency accuracy (battery mode)
50/60 Hz ±0.05%
Synchronous speed
From 1 Hz/s to 10 Hz/s (programmable)
Total performance in On-line mode
7.5÷60 kVA: 92.0%÷93.0% / 80÷200 kVA: 94.0%÷95.0%
Admissible overloads
125% for 10 min / 150% for 60 s / >150% for 20ms
Crest factor
3,4 a 1
MANUAL BYPASS
Protections
No breaks
STATIC BYPASS
Type and activation criteria
Solid state, controlled by microprocessor
Transfer times in On-line
Nil
Transfer to bypass
Immediate, for overloads exceeding 150%
Retransfer
Automatic, after alarm deactivation
Peak Shaving
User configurable activation
BATTERY
Battery type
Lead acid, sealed, maintenance free
Charging voltage regulation
Batt-Watch
Peak shaving function
Sizing for energy storage and supplying the load’s peaks in demand
COMMUNICATION
Ports
1 x RS232/RS485 + 1xUSB,with Modbus protocol
Relay interface
4 x AC failure, bypass, low battery and general
Intelligent slot
1, for SNMP
Monitoring software
Viewpower / UPSMAN
Backlit LCD display
LCD display, LEDs and keyboard
GENERAL
Operating temperature
0º C ÷ +40º C
Relative humidity
Up to 95%, non-condensing
Maxium operating altitude
2.400 m.s.n.m. (3)
Acoustic noise at 1 metre
<52 dB(A)(4)
IMPLEMENTATIONS
Nº Cabinets (Ups + BAT)
1 + 0
STANDARDS
Safety
EN-IEC 62040-1
Electromagnetic compatibility (EMC)
EN-62040-2
Operation
VFI-SS-11 (EN-62040-3)
Corporate cerification
ISO 9001, ISO 14001, ISO 45001
DIMENSIONS
Depth (mm)
770
Width (mm)
450
Height (mm)
1100
WEIGHT
Weight (kg)
0
(1) Up to 100 kVA.
(2) Only for three-phase input/output models. PF=0.8 for all other configurations.
(3) Power degradation for higher altitudes up to a maximum of 5,000 masl.
(4) <65 dB(A) for 80 to 120 kVA models / <70 dB(A) for 160 to 200 kVA models.
View distributor
Select Region and Country/Province to view Distributors
Accessories
Communications
AS-400 GX5 CON_R_AUX4
Relay interface for configuring inputs/outputs and switching contacts as required, up to 4 inputs/outputs.
Code: 663AA002213
EAN: 8436035929450
CS141 SENSOR CABLE
SNMP Card adapter cable for temperature and humidity sensor.
Code: 663AA002270
EAN: 8436584876298
MODEM GSM4G SMS BOX CS141-6 GX
GSM modem with an additional safety measure whereby coordinators and responsible technicians receive an SMS immediately if a fault occurs in the UPS system.
Code: 663AA002264
EAN: 8436584875406
NIMBUS ROUTER 4G
Device that uses 4G mobile networks to provide Internet connection via WiFi or Ethernet.
Code: 663AA002241
EAN: 8436584876281
NIMBUS SNMP Card
Nimbus Ethernet adapter / SNMP web adapter. Connection to the Salicru cloud (IoT - MQTT). Modbus TCP and RS232 protocol. SNMP V2. Shutdown of servers, via RCCMD software.
Code: 663AA002223
EAN: 8436584876274
SENSORMANAGER II CS141/CS121
Control unit allowing the connection of analogue and digital sensors for strategic room monitoring. 8 analogue inputs, 4 digital inputs and 4 digital outputs.
Code: 663AA002220
EAN: 8436584876267
SNMP Card GX5 CS141BSC-6
Ethernet adapter / SNMP web adapter. Modbus TCP protocol. SNMP V2 and V3. Shutdown of servers, by means of RCCMD software.
Code: 663AA002254
EAN: 8436584874270
SNMP RTH BOX GX5 CS141LM-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS485 protocol. SNMP V2 and V3. Outdoor location. Shutdown of servers, by means of RCCMD software. Connection with sensors and actuators.
Code: 663AA002260
EAN: 8436584875550
SNMP RTH CARD GX5 CS141SCM-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS485 protocol. SNMP V2 and V3. Shutdown of servers, via RCCMD software. Connection with sensors and actuators.
Code: 663AA002265
EAN: 8436584874881
SNMP TH BOX GX5 CS141-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS232 protocol. SNMP V2 and V3. Outdoor location. Shutdown of servers, via RCCMD software. Connection with sensors and actuators.
Code: 663AA002256
EAN: 8436584875536
SNMPTH CARD GX5 CS141SC-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS232 protocol. SNMP V2 and V3. Shutdown of servers, via RCCMD software. Connection with sensors and actuators.
Code: 663AA002259
EAN: 8436584875543
Software RCCMD
Application that allows the simultaneous and safe shutdown of different servers remotely. Communication via SNMP.
Code: 663AA002119
EAN: 8436584875246
SOFTWARE UNMS II-150
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 150 licenses.
Code: 663AA002141
EAN: 8436584876236
SOFTWARE UNMS II-200
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 200 licences.
Code: 663AA002261
EAN: 8436584874577
SOFTWARE UNMS II-25
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 25 licenses.
Code: 663AA002139
EAN: 8436584870388
SOFTWARE UNMS II-50
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 50 licenses.
Code: 663AA002140
EAN: 8436584876229
SOFTWARE UNMS II-9
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 9 licenses.
Code: 663AA002138
EAN: 8436035923212
Software UPSMAN
Application that allows simultaneous and safe shutdown of computers that are directly connected to the UPS via USB or serial network port.
Code: 663AA002123
EAN: 8436584876212
SOFTWARE VIEWPOWER
Viewpower is an advanced UPS management and administration software. It allows remote monitoring and remote management of one to several UPS in a network environment, either LAN or Internet. Downloadable via web.
Code: 663AA999998
T GX Sensor
Temperature sensor (range -25º C to +100º C). Compatible SNMP Card adapter required.
Code: 663AA002129
EAN: 8436035923953
T+H GX Sensor
Temperature sensor (range -25º C to +100º C) and relative humidity (range 0% to 100%). SNMP compatible SNMP Card adapter required
Code: 663AA002128
EAN: 8436035923946
Generic
CABLE PARALELO CUBE3+
Communication cables required to manage the parallel system of two devices. One cable is required for each device that forms the parallel system. 5 metres long
Code: 663AC000075
Empty Batt Mod 1x62 of 24 Ah for SLC CUBE3+
Battery cabinet without batteries prepared for installation 1 branch of 62 batteries of 24 Ah for UPS models series SLC CUBE3+.
Code: O6819999998
Empty Batt Mod 1x62 of 45 Ah for SLC CUBE3+
Battery cabinet without batteries prepared for installation 1 branch of 62 batteries of 45 Ah for UPS models series SLC CUBE3+.
Code: O6819999997
Empty Batt Mod 2x62 of 7 / 9 / 12 Ah for SLC CUBE3+
Battery cabinet without batteries prepared for the installation of 2 branches of 62 7 / 9 / 12 Ah batteries for UPS models SLC CUBE3+ series.
Code: O6819999999
External Maintenance By-pass SLC CUBE3+
External manual bypass for maintenance operations, electrically isolating the equipment. Bypass type with overlapping, ‘make before break’. For UPS series SLC CUBE3+.
Code: 681OP999999
Downloads
Documents
Data sheet
Catalogues
General Catalogue
Manuals
Certificates & Declarations
Instructions
Software
VIEWPOWER HTML
Windows
installViewPower_Windows - 109MB Download
Software questions about SLC-20-CUBE3+ PS 62AB356?
Request information about SLC-20-CUBE3+ PS 62AB356
Welcome to Salicru. Select country/language
Algeria Français
Angola Português
Bahrain English
Congo Français
Côte d'Ivoire Français
Egypt English
Iraq English
Jordan English
Kenya English
Kuwait English
Lebanon English
Libya English
Madagascar Français
Mali Français
Mauritania Français
Morocco Français
Niger Français
Nigeria English
Oman English
Qatar English
Reunion Français
Saudi Arabia English
Senegal Français
South Africa English
Syria English
Tanzania Français
Turkey English
Uganda English
United Arab Emirates English
extralarge
large
tablet
mobile
We use proprietary and third-party cookies to keep track of how our website is used and to be able to improve it,
adapt the content to your tastes and personalise our advertising, marketing and social media posts.
Click on the corresponding buttons to accept all of them, reject them or configure your settings.
Please see our Cookie Policy for more information.












MONTAWEB.com