SPS 16 ATS
Specifications
Technical specifications
INPUT
Voltage
200 / 208 / 220 / 230 / 240
Voltage range
150 ÷ 300 Vac
Rated frequency
50 / 60 Hz
OUTPUT
Voltage
200 / 208 / 220 / 230 / 240
Rated current (A)
16 A
Performance
>99%
COMMUNICATION
Interface
RS-232, USB and potential-free contacts
INDICATIONS
Information
Source A, source B, failure, overload, alarm, audible alarm silencer
Monitoring software
Yes, for Windows OS
Type
LCD + LEDs
Values
Voltage, current, frequency, % load, error code
CONNECTIONS
Input
2 x IEC C20
Output
8x IEC C13 + 1x IEC C19
PROTECTION
Output
Overload
GENERAL
Operating temperature
0ºC ÷ +40ºC
Relative humidity
Up to 95%, non-condensing
Maxium operating altitude
2,400 masl
STANDARDS
Safety
IEC-60950-1
Electromagnetic compatibility (EMC)
EN-55022; EN-55024
Corporate cerification
ISO 9001, ISO 14001, ISO 45001
DIMENSIONS
Depth (mm)
275
Width (mm)
438
Height (mm)
44
WEIGHT
Weight (kg)
4
It’s recommended to keep a front distance of 35mm, parallel to the fixing plane of the ears on the rack cabinet. This distance is not included in the “Depth” total dimension.
View distributor
Select Region and Country/Province to view Distributors
Accessories
Communications
AS-400 GX5 CON_R_AUX4
Relay interface for configuring inputs/outputs and switching contacts as required, up to 4 inputs/outputs.
Code: 663AA002213
EAN: 8436035929450
CS141 SENSOR CABLE
SNMP Card adapter cable for temperature and humidity sensor.
Code: 663AA002270
EAN: 8436584876298
NIMBUS ROUTER 4G
Device that uses 4G mobile networks to provide Internet connection via WiFi or Ethernet.
Code: 663AA002241
EAN: 8436584876281
RS-485 MODBUS CARD
Nimbus RS485 card with MODBUS protocol.
Code: 697OP000002
EAN: 8436035924127
SENSORMANAGER II CS141/CS121
Control unit allowing the connection of analogue and digital sensors for strategic room monitoring. 8 analogue inputs, 4 digital inputs and 4 digital outputs.
Code: 663AA002220
EAN: 8436584876267
SNMP Card GX5 CS141BSC-6
Ethernet adapter / SNMP web adapter. Modbus TCP protocol. SNMP V2 and V3. Shutdown of servers, by means of RCCMD software.
Code: 663AA002254
EAN: 8436584874270
SNMP RTH BOX GX5 CS141LM-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS485 protocol. SNMP V2 and V3. Outdoor location. Shutdown of servers, by means of RCCMD software. Connection with sensors and actuators.
Code: 663AA002260
EAN: 8436584875550
SNMP RTH CARD GX5 CS141SCM-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS485 protocol. SNMP V2 and V3. Shutdown of servers, via RCCMD software. Connection with sensors and actuators.
Code: 663AA002265
EAN: 8436584874881
SNMP TH BOX GX5 CS141-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS232 protocol. SNMP V2 and V3. Outdoor location. Shutdown of servers, via RCCMD software. Connection with sensors and actuators.
Code: 663AA002256
EAN: 8436584875536
SNMPTH CARD GX5 CS141SC-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS232 protocol. SNMP V2 and V3. Shutdown of servers, via RCCMD software. Connection with sensors and actuators.
Code: 663AA002259
EAN: 8436584875543
SOFTWARE UNMS II-100
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 100 licenses.
Code: 663AA002212
EAN: 8436584871897
SOFTWARE UNMS II-150
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 150 licenses.
Code: 663AA002141
EAN: 8436584876236
SOFTWARE UNMS II-200
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 200 licences.
Code: 663AA002261
EAN: 8436584874577
SOFTWARE UNMS II-25
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 25 licenses.
Code: 663AA002139
EAN: 8436584870388
SOFTWARE UNMS II-50
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 50 licenses.
Code: 663AA002140
EAN: 8436584876229
SOFTWARE UNMS II-9 (Salicru SNMP)
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Downloadable via web. Via SNMP adapter.
Code: 663AA999996
SOFTWARE VIEWPOWER
Viewpower is an advanced UPS management and administration software. It allows remote monitoring and remote management of one to several UPS in a network environment, either LAN or Internet. Downloadable via web.
Code: 663AA999998
T GX Sensor
Temperature sensor (range -25º C to +100º C). Compatible SNMP Card adapter required.
Code: 663AA002129
EAN: 8436035923953
T+H GX Sensor
Temperature sensor (range -25º C to +100º C) and relative humidity (range 0% to 100%). SNMP compatible SNMP Card adapter required
Code: 663AA002128
EAN: 8436035923946
Downloads
Documents
Data sheet
Catalogues
Manuals
Certificates & Declarations
Instructions
Request information about SPS 16 ATS
Welcome to Salicru. Select country/language
Australia English
Bangladesh English
Camboya English
China English
India English
Indonesia English
Japan English
Kazakhstan English
Laos English
Malaysia English
Myanmar English
New Zealand English
Pakistan English
Philippines English
Singapore English
South Korea English
Sri Lanka English
Taiwan English
Thailand English
Vietnam English
extralarge
large
tablet
mobile
We use proprietary and third-party cookies to keep track of how our website is used and to be able to improve it,
adapt the content to your tastes and personalise our advertising, marketing and social media posts.
Click on the corresponding buttons to accept all of them, reject them or configure your settings.
Please see our Cookie Policy for more information.














MONTAWEB.com