SLC TWIN RT2 4-10 kVA
On-line double-conversion tower/rack UPS from 4 kVA to 10 kVA with PF=1
High reliability in critical server environments

Salicru’s SLC TWIN RT2 series models are uninterruptible power supplies with unrivalled electrical protection features for critical server environments. Their dual tower/rack format offers physical adaptability to any site and, together with the built-in PDU strip, provides maximum ease of connection of the loads to be protected. In addition, their unity output power factor (VA=W) increases the power density delivered and reduces the space required for the installation of the UPS.

The LCD screen is swivel-mounted according to the mounting format chosen for ease of handling. In terms of serial communications, they feature USB, RS-232 and relay interfaces, as well as a smart slot to optionally accommodate an SNMP card, MODBUS or potential-free contacts; also available are software packages for local or virtual monitoring and management of the protected devices.

For applications that require extended backup, additional battery modules and/or solutions with extra charger can be installed. And for applications that require redundant protection or increase the need for power, there is the option of connecting up to 3 devices in parallel.
Characteristics
Applications

Guaranteed operability for IT environments

Numerous environments can be protected by Salicru’s SLC TWIN RT2 series UPSs, such as virtualised or non-virtualised server systems, voice and data networks, ERP systems, CRM solutions, document management, etc., all of whose operability depends on the reliability of the electrical supply that powers them.

Performances
On-line double-conversion technology
Output power factor PF=1
Convertible tower/rack format
Parallelable up to 3 units
Swivel-mount control panel
RS232 and USB-HID communication interfaces
Smart slot for SNMP and relays
Available backup extensions
Eco-mode operation
SLC Greenergy Solutions
Management software
PDU strip for distribution of output loads
Online double-conversion

Provides the highest level of security and reliability for protected critical loads, owing to the double conversion between the input and output and from AC to DC and DC to AC, thereby supplying a pure, stable, clean sine-wave voltage at the output, without any outages.

Tower/rack convertible format

This device can be mounted in rack format, using the standard adapters (lugs) supplied, or in tower format on the plinths (also supplied), which keep the UPS in a secure and stable vertical position. To enhance functionality, the display can easily be rotated so that its orientation is in line with the chosen use of the device. Maximum adaptability for one of the best single-phase UPS systems on the market.

PDU strip included

In addition to the terminal connections provided at the rear, the SLC TWIN RT2 series of 4 to 10kW devices are supplied with a separate PDU strip, with IEC C13 and C19 sockets in configurations that are adapted in line with the power rating of the UPS. Each group of sockets also boasts resettable thermal overload protection of 10 or 16A, depending on the socket version.

Higher power density
With a unity output power factor, maximum power in watts (W) is delivered, thereby optimising the always limited space in racks or server rooms.
Parallel redundant

A configuration of several UPS of the same capacity connected in parallel to a common output bus is possible to prevent any failure in one of the UPS from stopping the loads.

Optional extended back-up time

For processes that require longer autonomy, this UPS allows more back-up time by additional battery modules.

Connections
  1. Input/output terminals.
  2. RS-232 interface.
  3. Smart slot for SNMP/potential-free contacts/ MODBUS.
  4. Emergency stop (EPO).
  5. Connection for battery module (only in models with extra charger).
  6. Input circuit breaker.
  7. Parallel port.
  8. Current distribution port.
  9. Digital input/output.
Models
Power (VA)
UPDATE
Type
UPDATE
PDU sockets
UPDATE
Showing 1 - 10 of 10 products
KIT SLC-4000-TWIN RT2
Power (VA): 4000
Type: UPS Standard
PDU sockets: 4 x IEC-C13 + 2 x IEC-C19
KIT SLC-5000-TWIN RT2
Power (VA): 5000
Type: UPS Standard
PDU sockets: 4 x IEC-C13 + 2 x IEC-C19
KIT SLC-6000-TWIN RT2
Power (VA): 6000
Type: UPS Standard
PDU sockets: 4 x IEC-C13 + 2 x IEC-C19
KIT SLC-8000-TWIN RT2
Power (VA): 8000
Type: UPS Standard
PDU sockets: 2 x IEC-C13 + 4 x IEC-C19
KIT SLC-10000-TWIN RT2
Power (VA): 10000
Type: UPS Standard
PDU sockets: 2 x IEC-C13 + 4 x IEC-C19
SLC-4000-TWIN RT2 B1
Power (VA): 4000
Type: UPS with extra charger without batteries
PDU sockets: 4 x IEC-C13 + 2 x IEC-C19
SLC-5000-TWIN RT2 B1
Power (VA): 5000
Type: UPS with extra charger without batteries
PDU sockets: 4 x IEC-C13 + 2 x IEC-C19
SLC-6000-TWIN RT2 B1
Power (VA): 6000
Type: UPS with extra charger without batteries
PDU sockets: 4 x IEC-C13 + 2 x IEC-C19
SLC-8000-TWIN RT2 B1
Power (VA): 8000
Type: UPS with extra charger without batteries
PDU sockets: 2 x IEC-C13 + 4 x IEC-C19
SLC-10000-TWIN RT2 B1
Power (VA): 10000
Type: UPS with extra charger without batteries
PDU sockets: 2 x IEC-C13 + 4 x IEC-C19
Showing 1 - 10 of 10 products
Request information about SLC TWIN RT2 4-10 kVA

To contact Salicru directly or request information about any of our products, please fill in the following details and press send.

Please enter your name
Please indicate the position
Please indicate the position
Please enter your email
Please enter your address
Please enter your post code
Please enter your town/city
Please enter your country
Please enter your enquiryRequired field
INFORMATION ON DATA PROTECTION OF SALICRU S.A.

Purposes: To send you information about our products, including by electronic means.

Legitimacy: Consent of the interested party. Recipients: No transfers of data to third parties are anticipated, except in the event of legal requirement.

Rights: You can withdraw your consent at any time, and exercise your rights of data access, rectification, erasure and other rights at rgpd@salicru.com, as explained in the Privacy Policy.

Additional information: You can find additional information by clicking on Legal Notice.

I wish to receive commercial information, including by electronic means.
   
Indicate if you want to receive the newsletter
Please read and accept the privacy policy
* Required field.
Barcelona Web Design: MontawebMONTAWEB.com
Welcome to Salicru. Select country/language
Australia   English
Bangladesh   English
Camboya   English
China   English
India   English
Indonesia   English
Japan   English
Kazakhstan   English
Laos   English
Malaysia   English
Myanmar   English
New Zealand   English
Pakistan   English
Philippines   English
Singapore   English
South Korea   English
Sri Lanka   English
Taiwan   English
Thailand   English
Vietnam   English
extralarge
large
tablet
mobile
We use proprietary and third-party cookies to keep track of how our website is used and to be able to improve it, adapt the content to your tastes and personalise our advertising, marketing and social media posts. Click on the corresponding buttons to accept all of them, reject them or configure your settings. Please see our Cookie Policy for more information.