SLC-20-CUBE3+ A B1
SLC-20-CUBE3+ A B1
20 kVA three-phase Uninterruptible Power Supply System with extra charger
Energy efficiency with superior electrical protection
Input voltage (V):
115 / 120 / 127 / 133 V - 3 x 200 / 3 x 208 / 3 x 220 / 3 x 230 (3F + N)
Output voltage (V):
3 x 200 / 3 x 208 / 3 x 220 / 3 x 230 (3F + N)
Power (VA):
20000
Type:
UPS with extra charger
Code: 681LF000001
Specifications
Technical specifications
TECHNOLOGY
On-line, double conversion, HF, DSP control
INPUT
Rated voltage
Single-phase 115 / 120 / 127 / 133 V(1) / Three-phase 3 x 200 / 3 x 208 / 3 x 220 / 3 x 230 (3F + N)
Voltage range
+15% / -20% (configurable)
Rated frequency
50 / 60 Hz
Total harmonic distortion (THDi)
100% load: <1.5% / 50% load: <2.5% / 10% load: <6.0%
Power factor
1 from 10% load
Rectifier topology
Three-phase IGBT full wave, soft start, PFC, transformerless
OUTPUT
Power factor
0.9
Rated voltage
Single-phase 115 / 120 / 127 / 133 V(1) / Three-phase 3 x 200 / 3 x 208 / 3 x 220 / 3 x 230 (3F + N)
Dynamic accuracy
± 2% dynamic
Static accuracy
± 1% steady
Response time accuracy
20 ms for load steps 0% ÷ 100% and voltage drop up to -5%
Power (VA/W)
20000 / 18000
Total harmonic distortion (THDv) Linerar load
<0.5%
Total harmonic distortion (THDv) Non~linear load
<1,5% (EN-62040-3)
Synchronised frequency
50/60 Hz ±5 Hz (selectable)
Frequency
50 / 60 Hz
Frequency accuracy (battery mode)
50/60 Hz ±0.05%
Synchronous speed
From 1 Hz/s to 10 Hz/s (programmable)
Total performance in On-line mode
5÷30 kVA: 90%÷92% / 40÷100 kVA: 92%÷93%
Admissible overloads
125% for 10 min / 150% for 60 s / >150% for 20ms
MANUAL BYPASS
Protections
No breaks
STATIC BYPASS
Type and activation criteria
Solid state, controlled by microprocessor
Transfer times in Smart Eco-mode
4 ms (typical)
Transfer times in On-line
Null
Transfer to bypass
Immediate, for overloads exceeding 150%
Retransfer
Automatic, after alarm deactivation
BATTERY
Battery type
Lead acid, sealed, maintenance free
Charging voltage regulation
Batt-Watch
COMMUNICATION
Ports
1 x RS232/RS485 + 1xUSB,with Modbus protocol
Relay interface
4 x AC failure, bypass, low battery and general
Intelligent slot
1, for SNMP
Monitoring software
Viewpower / UPSMAN
Backlit LCD display
LCD display, LEDs and keyboard
GENERAL
Operating temperature
0º C ÷ +40º C
Relative humidity
Up to 95%, non-condensing
Maxium operating altitude
2,400 masl
Acoustic noise at 1 metre
<52 dB(A)(2)
IMPLEMENTATIONS
Nº Cabinets (Ups + BAT)
1+0
STANDARDS
Safety
EN-IEC 62040-1
Electromagnetic compatibility (EMC)
EN-62040-2
Operation
VFI-SS-11 (EN-62040-3)
Corporate cerification
ISO 9001, ISO 14001, ISO 45001
DIMENSIONS
Depth (mm)
775
Width (mm)
450
Height (mm)
1100
WEIGHT
Weight (kg)
175
(1) Up to 30 kVA.
(2) <65 dB(A) for 40 to 60 kVA models / <70 dB(A) for 80 to 100 kVA models
View distributor
Select Region and Country/Province to view Distributors
Accessories
Generic
BM-CUBE3+ A L-P-20-1/1
External Manual Bypass for SLC CUBE3+ A 20 kVA series equipment with single-phase input and output configuration. Allows maintenance to be carried out without interrupting the power supply to the protected equipment.
Code: 681OP000241
BM-CUBE3+ A MB-P-20-1/2
External Manual Bypass for SLC CUBE3+ A 20 kVA series equipment with single-phase input and three-phase output configuration. Allows maintenance to be carried out without interrupting the power supply to the protected equipment.
Code: 681OP000219
BM-CUBE3+ A NB-P-20-2/1
External Manual Bypass for SLC CUBE3+ A 20 kVA series equipment with three-phase input and single-phase output configuration. Allows maintenance to be carried out without interrupting the power supply to the protected equipment.
Code: 681OP000195
BM-CUBE3+ A P-20-2/2
External Manual Bypass for SLC CUBE3+ A 20 kVA series equipment with single-phase input and output configuration. Allows maintenance to be carried out without interrupting the power supply to the protected equipment.
Code: 681OP000180
CAB SLC BZ192 DB9M/DB9H 1.8m
Communication extension cable, DB9M/DB9H connectors, 1.8m length
Code: 663AC000005
CAB SLC BZ192 DB9M/DB9H 10m
Communication extension cable, DB9M/DB9H connectors, 10 m long
Code: 663AC000006
CAB SLC BZ192 DB9M/DB9H 3m
Communication extension cable, DB9M/DB9H connectors, 3m length
Code: 663AC000004
CAB SLC BZ192 DB9M/DB9H 5m
Communications extension cable, DB9M/DB9H connectors, 5m length
Code: 663AC000003
CABLE PARALELO CUBE3+
Communication cables required to manage the parallel system of two devices. One cable is required for each device that forms the parallel system. 5 metres long
Code: 663AC000075
Downloads
Documents
Data sheet
Catalogues
Manuals
Certificates & Declarations
Instructions
Software
VIEWPOWER HTML
Windows
installViewPower_Windows - 109MB Download
Software questions about SLC-20-CUBE3+ A B1?
Request information about SLC-20-CUBE3+ A B1
Welcome to Salicru. Select country/language
Argentina Español
Bolivia Español
Brazil Português
Caribbean Islands English
Chile Español
Colombia Español
Costa Rica Español
Cuba Español
Dominican Republic Español
Ecuador Español
El Salvador Español
Guatemala Español
Mexico Español
Nicaragua Español
Panama Español
Paraguay Español
Peru Español
United States English
Uruguay Español
Venezuela Español
extralarge
large
tablet
mobile
We use proprietary and third-party cookies to keep track of how our website is used and to be able to improve it,
adapt the content to your tastes and personalise our advertising, marketing and social media posts.
Click on the corresponding buttons to accept all of them, reject them or configure your settings.
Please see our Cookie Policy for more information.
















MONTAWEB.com