SLC-#/10-ADAPT 40X
SLC-#/10-ADAPT 40X
Modular three-phase Uninterruptible Power Systems of up to 40000 VA
Modularity, optimisation and efficiency in electrical safety for data centres
Module power (VA / W):
10000 / 10000
Input voltage (V):
3x208/220/380/400/415 V
Output voltage (V):
3x208/220/380/400/415 V
System power (VA/W):
40000 / 40000
Code: 694OQ000016
Specifications
Technical specifications
TECHNOLOGY
On-line double-conversion, HF, DSP control
PHYSICAL
Module/System
Sistema
No. Modules (#)
1 to 4
INPUT
Rated single phase voltage
120/127/220/230/240 V
Rated three-phase voltage (3P+ N + E)
3x208/220/380/400/415 V
Voltage range
-40% +15% (1)
Rated frequency
50 / 60 Hz
Frequency range
40 - 70 Hz
Total harmonic distortion (THDi)
≤4%
Power factor
>0.99
OUTPUT
Power factor
1
Single phase rated voltage
120/127/220/230/240 V
Rated three-phase voltage (3P + N + E)
3x208/220/380/400/415 V
Dynamic accuracy
±1.5%
Static accuracy
±1%
Power (VA/W)
40000 / 40000
Maximum power (VA/W)
40000 / 40000
Total harmonic distortion (THDv) Linerar load
<1%
Total harmonic distortion (THDv) Non~linear load
<5,5%
Frequency
50 / 60 Hz
Total performance in On-line mode
95%
Performance in Smart Eco-mode
98%
Admissible overloads
<110% for 1 hour / <125% for 10 min / <150% for 1 min / >150% for 200 ms
Admissible overloads
<110% for 1 hour / <125% for 10 min / <150% for 1 min / >150% for 200 ms
MANUAL BYPASS
Protections
Uninterrupted
STATIC BYPASS
Type
Static thyristor
Three-phase voltage (V)
3x208/220/380/400/415 V
Transfer time
0 ms
Voltage range
-40% +20%
Admissible overloads
<110% permanent / <150% for 1 min
BATTERY
Battery type
Pb-Ca, lead acid, gel, Ni-Cd
Charging voltage regulation
Batt-watch
Charger maximum power (W)
20% of total system power
COMMUNICATION
Display
7” touchscreen, LEDs and keypad
Ports
RS-232, RS-485 and relays
Intelligent slot
1 x SNMP
GENERAL
Operating temperature
0º C ÷ +40º C
Relative humidity
Up to 95%, non-condensing
Maxium operating altitude
<2,400 masl(2)
Acoustic noise at 1 metre
<56 dB(A)
SYSTEMS
Maximum no. modules systems
7
Maximum power per parallel system (kVA)
280
STANDARDS
Safety
EN-IEC 62040-1
Electromagnetic compatibility (EMC)
EN-IEC 62040-2
Operation
VFI-SS-111 (EN-IEC 62040-3)
Corporate cerification
ISO 9001, ISO 14001, ISO 45001
DIMENSIONS
Depth (mm)
697
Width (mm)
485
Height (mm)
575
WEIGHT
Weight (kg)
66
(1) Depending on charge.
(2) Power degradation for higher altitudes, up to a maximum of 5,000 masl.
(3) Systems with 2 or 3 modules for 3x220V voltages / Systems with 2, 4 or 6 modules for 3x400 V voltages.
View distributor
Select Region and Country/Province to view Distributors
Downloads
Documents
Data sheet
Catalogues
Manuals
Certificates & Declarations
Instructions
Request information about SLC-#/10-ADAPT 40X
Welcome to Salicru. Select country/language
Argentina Español
Bolivia Español
Brazil Português
Caribbean Islands English
Chile Español
Colombia Español
Costa Rica Español
Cuba Español
Dominican Republic Español
Ecuador Español
El Salvador Español
Guatemala Español
Mexico Español
Nicaragua Español
Panama Español
Paraguay Español
Peru Español
United States English
Uruguay Español
Venezuela Español
extralarge
large
tablet
mobile
We use proprietary and third-party cookies to keep track of how our website is used and to be able to improve it,
adapt the content to your tastes and personalise our advertising, marketing and social media posts.
Click on the corresponding buttons to accept all of them, reject them or configure your settings.
Please see our Cookie Policy for more information.
















MONTAWEB.com