SLC-200-XPERT B1
SLC-200-XPERT B1
Uninterruptible Power Systems three-phase from 200 kVA
High critical power facilities protected by high functionalities
Input voltage (V):
3 x 380 V / 3 x 400 V / 3 x 415 V (3F+N)
Output voltage (V):
3 x 380 V / 3 x 400 V / 3 x 415 V (3F+N)
System power (VA/W):
200000 / 200000
Code: 695KA000006
Specifications
Technical specifications
TECHNOLOGY
On-line, double-conversion, DSP control
INPUT
Voltage
3 x 380 V / 3 x 400 V / 3 x 415 V (3F+N)
Voltage range
+15% / -20% (@ 3 x 400 V)
Rated frequency
50 / 60 Hz (45-65 Hz)
Frequency range
±10%
Total harmonic distortion (THDi)
<3%
Power factor
>0.99
OUTPUT
Power factor
1
Voltage
3 x 380 V / 3 x 400 V / 3 x 415 V (3F+N)
Total harmonic distortion (THDv) Non~linear load
<5%
Synchronised frequency
±2 Hz
Frequency
50 / 60 Hz
Frequency accuracy (battery mode)
±0.001 Hz
Synchronous speed
<1Hz/s
High-efficiency performance
Up to 97%
Total performance in On-line mode
≥95%
Performance in Smart Eco-mode
≥98%
Admissible overloads
125% for 10 min / 150% for 1 min
Crest factor
3 a 1
STATIC BYPASS
Type and activation criteria
Solid state, microprocessor controlled
Voltage (V)
Three-phase 3 x 380 V / 3 x 400 V / 3 x 415 V (3P+N)
Transfer to bypass
Immediate, for overloads exceeding 150%
Retransfer
Automatic after alarm discontinuation
Frequency range
±10% (selectable)
Voltage range
±10% (selectable)
Input
Independent
Frequency
50 / 60 Hz
Admissible overloads
1000% for 1 cycle
BATTERY
Battery type
Lead acid, sealed, maintenance free(1)
Charge type
Type of charge IU (DIN 41773)
COMMUNICATION
Ports
RS-232, USB
Backlit LCD display
10” touch screen
GENERAL
Operating temperature
0 ÷ +40ºC
Storage temperature
-10ºC ÷ +40ºC (with battery) / -10ºC ÷ +70ºC (no battery)
Relative humidity
95% non-condensing
Maxium operating altitude
2400 m.a.s.l. (2)
Acoustic noise at 1 metre
<60dB up to 160kVA; <65dB up to 300kVA;<72dB for 400kVA
STANDARDS
Safety
EN-IEC 62040-1
Electromagnetic compatibility (EMC)
EN-62040-2
Operation
VFI-SS-11 (EN-62040-3)
Corporate cerification
ISO 9001, ISO 14001, ISO 45001
DIMENSIONS
Depth (mm)
970
Width (mm)
880
Height (mm)
1978
WEIGHT
Weight (kg)
720
(1) Ni-Cd, Li-Ion and other types of battery available on request.
(2) Power degradation up to 5,000 masl.
View distributor
Select Region and Country/Province to view Distributors
Accessories
Communications
AS-400 GX5 CON_R_AUX4
Relay interface for configuring inputs/outputs and switching contacts as required, up to 4 inputs/outputs.
Code: 663AA002213
EAN: 8436035929450
CS141 SENSOR CABLE
SNMP Card adapter cable for temperature and humidity sensor.
Code: 663AA002270
EAN: 8436584876298
MODEM GSM4G SMS BOX CS141-6 GX
GSM modem with an additional safety measure whereby coordinators and responsible technicians receive an SMS immediately if a fault occurs in the UPS system.
Code: 663AA002264
EAN: 8436584875406
NIMBUS ROUTER 4G
Device that uses 4G mobile networks to provide Internet connection via WiFi or Ethernet.
Code: 663AA002241
EAN: 8436584876281
NIMBUS SNMP Card
Nimbus Ethernet adapter / SNMP web adapter. Connection to the Salicru cloud (IoT - MQTT). Modbus TCP and RS232 protocol. SNMP V2. Shutdown of servers, via RCCMD software.
Code: 663AA002223
EAN: 8436584876274
RS-485 MODBUS CARD
Nimbus RS485 card with MODBUS protocol.
Code: 697OP000002
EAN: 8436035924127
SENSORMANAGER II CS141/CS121
Control unit allowing the connection of analogue and digital sensors for strategic room monitoring. 8 analogue inputs, 4 digital inputs and 4 digital outputs.
Code: 663AA002220
EAN: 8436584876267
SNMP Card GX5 CS141BSC-6
Ethernet adapter / SNMP web adapter. Modbus TCP protocol. SNMP V2 and V3. Shutdown of servers, by means of RCCMD software.
Code: 663AA002254
EAN: 8436584874270
SNMP RTH BOX GX5 CS141LM-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS485 protocol. SNMP V2 and V3. Outdoor location. Shutdown of servers, by means of RCCMD software. Connection with sensors and actuators.
Code: 663AA002260
EAN: 8436584875550
SNMP RTH CARD GX5 CS141SCM-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS485 protocol. SNMP V2 and V3. Shutdown of servers, via RCCMD software. Connection with sensors and actuators.
Code: 663AA002265
EAN: 8436584874881
SNMP TH BOX GX5 CS141-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS232 protocol. SNMP V2 and V3. Outdoor location. Shutdown of servers, via RCCMD software. Connection with sensors and actuators.
Code: 663AA002256
EAN: 8436584875536
SNMPTH CARD GX5 CS141SC-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS232 protocol. SNMP V2 and V3. Shutdown of servers, via RCCMD software. Connection with sensors and actuators.
Code: 663AA002259
EAN: 8436584875543
Software RCCMD
Application that allows the simultaneous and safe shutdown of different servers remotely. Communication via SNMP.
Code: 663AA002119
EAN: 8436584875246
SOFTWARE UNMS II-150
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 150 licenses.
Code: 663AA002141
EAN: 8436584876236
SOFTWARE UNMS II-200
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 200 licences.
Code: 663AA002261
EAN: 8436584874577
SOFTWARE UNMS II-25
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 25 licenses.
Code: 663AA002139
EAN: 8436584870388
SOFTWARE UNMS II-50
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 50 licenses.
Code: 663AA002140
EAN: 8436584876229
SOFTWARE UNMS II-9
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 9 licenses.
Code: 663AA002138
EAN: 8436035923212
Software UPSMAN
Application that allows simultaneous and safe shutdown of computers that are directly connected to the UPS via USB or serial network port.
Code: 663AA002123
EAN: 8436584876212
T GX Sensor
Temperature sensor (range -25º C to +100º C). Compatible SNMP Card adapter required.
Code: 663AA002129
EAN: 8436035923953
T+H GX Sensor
Temperature sensor (range -25º C to +100º C) and relative humidity (range 0% to 100%). SNMP compatible SNMP Card adapter required
Code: 663AA002128
EAN: 8436035923946
Generic
BM-XPERT-P-200-4/4
External Manual Bypass for 200 kVA SLC X-PERT Series equipment allows maintenance to be performed without interrupting power to the protected equipment.
Code: 695OQ000046
KIT PARALELO X-PERT 200-300KVA
Kit to connect up to 6 UPSs in parallel, to double power or provide the system with redundancy. For 200 to 300 kVA SLC X-PERT Series equipment. Cable length: 10m (one kit is required for each UPS)
Code: 695OQ000008
EAN: PARALLEL KIT ACC-BSN47-004
LOAD-SYNC X-PERT 200-300KVA
Additional interface board and communication cable (10m). Synchronizes the output voltage of two UPS connected to different distribution lines, for 200-300 kVA equipment of the SLC X-PERT series.
Code: 695OQ000014
EAN: ACC-BSN48-004
Downloads
Documents
Data sheet
Catalogues
Manuals
Certificates & Declarations
Instructions
Request information about SLC-200-XPERT B1
Welcome to Salicru. Select country/language
Armenia English
Belarus English
Bulgaria English
Croatia English
Cyprus English
Czech Republic English
Denmark English
Estonia English
Finland English
France Français
Georgia English
Greece English
Hungary English
Ireland English
Italy English
Latvia English
Lithuania English
Malta English
Netherlands English
Norway English
Poland English
Portugal Português
Romania English
Russia English
Serbia English
Slovakia English
Sweden English
Ukraine English
United Kingdom English
extralarge
large
tablet
mobile
We use proprietary and third-party cookies to keep track of how our website is used and to be able to improve it,
adapt the content to your tastes and personalise our advertising, marketing and social media posts.
Click on the corresponding buttons to accept all of them, reject them or configure your settings.
Please see our Cookie Policy for more information.
















MONTAWEB.com