Uninterruptible Power Systems three-phase from 15 kVA
The most advanced continuity protection on the market
Power (VA): 15000
Type: UPS Standard
Code: 6B3AA000003
Specifications
Technical specifications
TECHNOLOGY
On-line, double conversion, HF, DSP control
INPUT
Voltage
3 × 380 / 3 × 400 / 3 × 415 V (3F + N)
Voltage range
7.5÷20 kVA: 110÷300 V (F-N) / 30÷80 kVA: 115÷265 V (F-N)
Rated frequency
50 / 60 Hz
Frequency range
7,5 ÷ 20kVA: 40 ÷ 70Hz (1) / 30 ÷ 80kVA: 45 ÷ 65Hz
Total harmonic distortion (THDi)
7,5÷20 kVA: <4% / 30÷80 kVA: <3%
Power factor
7.5÷20 kVA: ≥0.99 / 30÷80 kVA: 1 from 10% load
Rectifier topology
Three-phase IGBT full wave, soft start, PFC, transformerless
OUTPUT
Power factor
1
Voltage
3 × 380 / 3 × 400 / 3 × 415 V (3F + N)
Dynamic accuracy
±10%
Static accuracy
7,5÷20 kVA: ±1% / 30÷80 kVA: ±0,5%
Power (VA/W)
15.000 / 15.000
Synchronised frequency
50/60 Hz ±5 Hz (selectable)
Frequency
50 / 60 Hz
Frequency accuracy (battery mode)
50/60 Hz ±0,1%
Eco-mode performance
hasta 98%
Total performance in On-line mode
>96% (2)
Admissible overloads
7.5 ÷ 20 kVA: 110% 60 min / 110~125% 10 min / 125~150% 60 s / >150% 1 s 30 ÷ 80 kVA: 125% 10 min / 125~135% 5 min / 135~150% 60 s / >150% immediate
Crest factor
3 a 1
MANUAL BYPASS
Protections
Uninterrupted
STATIC BYPASS
Type and activation criteria
Solid state
Transfer times in Smart Eco-mode
<10 ms
Transfer to bypass
Immediate, for overloads exceeding 150%
Retransfer
Automatic, after alarm deactivation
BATTERY
Battery type
Pb-Ca, VRLA, lead acid, gel, Ni-Cd, Li-Ion
Charging voltage regulation
Batt-Watch
COMMUNICATION
Ports
1xRS232 + 1xUSB
Relay interface
7.5÷20 kVA: 6 relays / 30÷80 kVA: 4 relays (programmable)
Intelligent slot
NIMBUS, SNMP, RS232, RS485, USB, AS400 or remote battery temperature(3)
Backlit LCD display
5” colour touch screen
GENERAL
Operating temperature
0º C ÷ +40º C (3)
Relative humidity
Up to 95%, non-condensing
Maxium operating altitude
2,400 masl (4)
Acoustic noise at 1 metre
7,5÷20 kVA: <59 dB / 30÷40 kVA: <54 dB / 60÷80 kVA: <61,5 dB
SYSTEMS
Maximum no. parallel systems
Sí, hasta 4 unidades.
IMPLEMENTATIONS
Nº Cabinets (Ups + BAT)
1
STANDARDS
Safety
IEC/EN 62040-1
Electromagnetic compatibility (EMC)
IEC/EN 62040-2 C3
Operation
VFI-SS-11 (EN-62040-3)
Corporate cerification
ISO 9001, ISO 14001, ISO 45001
DIMENSIONS
Depth (mm)
689
Width (mm)
250
Height (mm)
827
WEIGHT
Weight (kg)
118
(1) 1/1 options with power derating and 3/1 (under request) (2) According to the selected operating mode (3) For models 7,5-20 kVA = 1 Slot / For models 30-80 kVA = 2 Slots (4) Up to 55ºC with power derating (5) Power degradation for temperature altitudes, up to a maximum of 5,000 masl
3D
View distributor
Region
Select Region and Country/Province to view Distributors
Accessories
Communications
AS-400 GX5 CON_R_AUX4
Relay interface for configuring inputs/outputs and switching contacts as required, up to 4 inputs/outputs.
Code: 663AA002213
EAN: 8436035929450
CS141 SENSOR CABLE
SNMP Card adapter cable for temperature and humidity sensor.
Code: 663AA002270
EAN: 8436584876298
MODEM GSM4G SMS BOX CS141-6 GX
GSM modem with an additional safety measure whereby coordinators and responsible technicians receive an SMS immediately if a fault occurs in the UPS system.
Code: 663AA002264
EAN: 8436584875406
NIMBUS AS Card DB9 RT2
Nimbus AS400 board potential free contacts and DB9 connector.
Code: 663AA002231
EAN: 8436584870883
NIMBUS AS400 Card
Nimbus AS400 card with potential-free contacts.
Code: 663AA002222
EAN: 8436584870869
NIMBUS ROUTER 4G
Device that uses 4G mobile networks to provide Internet connection via WiFi or Ethernet.
Code: 663AA002241
EAN: 8436584876281
NIMBUS2 Mini SNMP Card
Nimbus2 Ethernet / SNMP web adapter. Mini card format. Connection to the Salicru cloud (IoT - MQTT). Modbus TCP and RS232 protocol. SNMP V2. Shutdown of servers, by means of RCCMD software.
Code: 663AA002286
EAN: 8436584872856
RS-485 MODBUS CARD
Nimbus RS485 card with MODBUS protocol.
Code: 697OP000002
EAN: 8436035924127
SENSORMANAGER II CS141/CS121
Control unit allowing the connection of analogue and digital sensors for strategic room monitoring. 8 analogue inputs, 4 digital inputs and 4 digital outputs.
Code: 663AA002220
EAN: 8436584876267
SNMP Card GX5S CS141MINI-6
Ethernet adapter / SNMP web adapter. Mini card format. Modbus TCP and RS232 protocol. SNMP V2 and V3. Shutdown of servers, via RCCMD software.
Code: 663AA002252
EAN: 8436584873853
SNMP RTH BOX GX5 CS141LM-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS485 protocol. SNMP V2 and V3. Outdoor location. Shutdown of servers, by means of RCCMD software. Connection with sensors and actuators.
Code: 663AA002260
EAN: 8436584875550
SNMP TH BOX GX5 CS141-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS232 protocol. SNMP V2 and V3. Outdoor location. Shutdown of servers, via RCCMD software. Connection with sensors and actuators.
Code: 663AA002256
EAN: 8436584875536
Software RCCMD
Application that allows the simultaneous and safe shutdown of different servers remotely. Communication via SNMP.
Code: 663AA002119
EAN: 8436584875246
SOFTWARE UNMS II-150
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 150 licenses.
Code: 663AA002141
EAN: 8436584876236
SOFTWARE UNMS II-200
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 200 licences.
Code: 663AA002261
EAN: 8436584874577
SOFTWARE UNMS II-25
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 25 licenses.
Code: 663AA002139
EAN: 8436584870388
SOFTWARE UNMS II-50
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 50 licenses.
Code: 663AA002140
EAN: 8436584876229
SOFTWARE UNMS II-9
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 9 licenses.
Code: 663AA002138
EAN: 8436035923212
Software UPSMAN
Application that allows simultaneous and safe shutdown of computers that are directly connected to the UPS via USB or serial network port.
Code: 663AA002123
EAN: 8436584876212
SOFTWARE VIEWPOWER
Viewpower is an advanced UPS management and administration software. It allows remote monitoring and remote management of one to several UPS in a network environment, either LAN or Internet. Downloadable via web.
Code: 663AA999998
T GX Sensor
Temperature sensor (range -25º C to +100º C). Compatible SNMP Card adapter required.
Code: 663AA002129
EAN: 8436035923953
T+H GX Sensor
Temperature sensor (range -25º C to +100º C) and relative humidity (range 0% to 100%). SNMP compatible SNMP Card adapter required
Code: 663AA002128
EAN: 8436035923946
Generic
BM-CUBE4-P-15-2/2
External Manual Bypass for SLC CUBE4 15 kVA series equipment with single-phase input and output configuration. Allows maintenance to be carried out without interrupting the power supply to the protected equipment.
Code: 6B3OP000013
BM-CUBE4-P-15-4/2
External Manual Bypass for SLC CUBE4 series equipment of 15 kVA with three-phase input and single-phase output configuration. Allows maintenance to be carried out without interrupting the power supply to the protected equipment.
Code: 6B3OP000021
BM-CUBE4-P-15-4/4
External Manual Bypass for SLC CUBE4 15 kVA series equipment with three-phase input and output configuration. Allows maintenance to be carried out without interrupting the power supply to the protected equipment.
Code: 6B3OP000003
CAB PAR CUBE4(-R) 7,5-20KVA
Communication cables needed to manage the parallel system of two equipments. One cable is required for each equipment forming the parallel system. 1.5 metres long
Code: 663AC000142
Autonomy
Autonomy curves
SLC-15-CUBE4 and SLC-15-CUBE4 B1
SLC-15-CUBE4
SLC-15-CUBE4 (6B3AB000008)
SLC-15-CUBE4 (6B3AB000037) + 1 x MOD BAT CUBE4 (6B3BT000010)
SLC-15-CUBE4 (6B3AB000009) + 1 x MOD BAT CUBE4 (6B3BT000007)
SLC-15-CUBE4 (6B3AB000031) + 1 x MOD BAT CUBE4 (6B3BT000086)
SLC-15-CUBE4 (6B3AB000040 ) + 2 x MOD BAT CUBE4 (6B3BT000009)
SLC-15-CUBE4 (6B3AB000032) + 1 x MOD BAT CUBE4 (6B3BT000027)
Downloads
Documents
Data sheet
Data Sheet SLC CUBE4
Catalogues
Product Catalogue SLC CUBE4
General Catalogue
Manuals
Installation SLC CUBE4 /R three phase in/out
Installation SLC CUBE4 /R -B three phase in/out
SLC CUBE4 /R -B single phase in/out installation
SLC CUBE4 /R single phase in/out installation
Installation SLC CUBE4 /R -B three-phase in/ single-phase out
Manual 30-80 kVA SLC CUBE4
Manual 7,5-20 kVA SLC CUBE4
Nimbus connectivity manual ETHERNET/SNMP/NIMBUS CLOUD NETWORK CARDS / AS400
Bypass box manual
Product guide SLC CUBE4
Dimensional Drawing SLC CUBE4
Manual Protocol Map SLC CUBE4
Manual Protocol Map (Nimbus)
Manual Protocol Map SLC CUBE4
Certificates & Declarations
Safety certificate SLC CUBE4
Declaration of conformity - CE SLC CUBE4
ISO 45001 certificate
ISO 9001 certificate
ISO 14001 certificate
Instructions
End Of Life Instructions SLC CUBE4
Safety instructions
Software
VIEWPOWER HTML
Windows
Windows
installViewPower_Windows - 109MB Download
Mac OS
Mac OS
ViewPowerHTML_MAC_x64_Intel. - 81.7MB Download
installViewPowerHTML_MAC_x64_Mchip - 79.1MB Download
Linux
Linux
ViewPowerHTML_Linux_x86_64 - 77MB Download
ViewPowerHTML_Linux_text_x86_64 - 116 MB Download
ViewPowerHTML_Linux_text_i386 - 77,9MB Download
ViewPowerHTML_Linux_i386 -77.3MB Download
Windows
Windows
ViewpowerHTML5 user's manual Download
Mac OS
Mac OS
ViewpowerHTML5 user's manual Download
Linux
Linux
ViewpowerHTML5 user's manual Download
Software questions about SLC-15-CUBE4?
Request information about SLC-15-CUBE4

To contact Salicru directly or request information about any of our products, please fill in the following details and press send.

Please enter your name
Please indicate the position
Please indicate the position
Please enter your email
Please enter your address
Please enter your post code
Please enter your town/city
Please enter your country
Please enter your enquiryRequired field
INFORMATION ON DATA PROTECTION OF SALICRU S.A.

Purposes: To send you information about our products, including by electronic means.

Legitimacy: Consent of the interested party. Recipients: No transfers of data to third parties are anticipated, except in the event of legal requirement.

Rights: You can withdraw your consent at any time, and exercise your rights of data access, rectification, erasure and other rights at rgpd@salicru.com, as explained in the Privacy Policy.

Additional information: You can find additional information by clicking on Legal Notice.

I wish to receive commercial information, including by electronic means.
   
Indicate if you want to receive the newsletter
Please read and accept the privacy policy
* Required field.
Barcelona Web Design: MontawebMONTAWEB.com
Welcome to Salicru. Select country/language
Australia   English
Bangladesh   English
Camboya   English
China   English
India   English
Indonesia   English
Japan   English
Kazakhstan   English
Laos   English
Malaysia   English
Myanmar   English
New Zealand   English
Pakistan   English
Philippines   English
Singapore   English
South Korea   English
Sri Lanka   English
Taiwan   English
Thailand   English
Vietnam   English
extralarge
large
tablet
mobile
We use proprietary and third-party cookies to keep track of how our website is used and to be able to improve it, adapt the content to your tastes and personalise our advertising, marketing and social media posts. Click on the corresponding buttons to accept all of them, reject them or configure your settings. Please see our Cookie Policy for more information.