SLC ADAPT2
Salicru’s SLC ADAPT2 series consists of modular On-line double conversion uninterruptible power supply (UPS) solutions with DSP control and three-level IGBT inverter technology.
Flexibility: It enables solutions to be configured from 25 kVA to 1500 kVA, thanks to the range of modules available (25 and 50 kVA), different configurable systems (8, 10 or 12 modules) and the parallel/redundant option of up to three 500 kVA systems. It also provides increased protection as needs grow - pay as you grow - thereby improving total cost of ownership (TCO).
Availability: Its hot-swap modules can be added or replaced during operation, thereby improving mean time to repair (MTTR) and reducing maintenance costs. In addition, the system’s remote management, which can be integrated into any platform, also facilitates operation. And the extensive back-up options available, along with intelligent battery charging, ensure continuous operation of the protected critical loads.
Reliability: Its DSP control, based on three-level PWM technology, improves response effectiveness and, along with shared load redundancy, significantly extends the mean time between failures (MTBF).
Redundant protection for critical applications
Data centres with all capacities, IT infrastructures, modular and virtualised data centres and applications for critical processes are some of the services that require high-level electrical protection to ensure reliable, continuous and high-quality operation, such as that provided by Salicru's SLC ADAPT2 series systems.
Wide range of configurations in cabinets of 2, 3 or 4 modules or cabinets of 8, 10 or 12 modules, enabling configurations from 1x25 kVA (25 kVA) to 12x50 kVA (600 kVA) in a single cabinet.
The widest range of configurations for medium-sized power solutions.
Possibility of configuring systems using cabinets in parallel with configurations from 1x25 kVA (25 kVA) to 3x500 kVA (1,500 kVA).
More power and flexibility for medium-sized facilities with the need for growth or high power
Modularity up to 1,500 kVA.
Configurable level of redundancy according to the needs of each facility, reaching levels of availability of 99.9999%.
Provides the facility with greater security, as it is a much more competitive solution than the traditional paralleling of UPSs.
Each cabinet incorporates a static bypass and a maintenance bypass(1) appropriate for the total power that it can assume.
Equipped for expansion of the total number of power modules without the need to reconfigure the cabinet every time the power is changed.
(1) Optional for systems with 10 and 15 kW modules.
- Manual bypass.
- Start-up from batteries (Cold Start).
- LCD display.
- Bypass module.
- Dry contacts.
- Extended relays and SNMP / Nimbus slot.
- USB, RS-232 and RS-485 interfaces.
- Power modules.