SLC-15-CUBE3+ A
SLC-15-CUBE3+ A
15 kVA three-phase Uninterruptible Power Supply System
Energy efficiency with superior electrical protection
Input voltage (V):
115 / 120 / 127 / 133 V - 3 x 200 / 3 x 208 / 3 x 220 / 3 x 230 (3F + N)
Output voltage (V):
3 x 200 / 3 x 208 / 3 x 220 / 3 x 230 (3F + N)
Power (VA):
15000
Type:
UPS Standard
Code: 681LF000049
Specifications
Technical specifications
INPUT
Rated voltage
Monofásica 115 / 120 / 127 / 133 V(1) / Trifásica 3 x 200 / 3 x 208 / 3 x 220 / 3 x 230 (3F + N)
Voltage range
+15% / -20% (configurable)
Rated frequency
50 / 60 Hz
Total harmonic distortion (THDi)
100% load: <1.5% / 50% load: <2.5% / 10% load: <6.0%
Power factor
1 from 10% load
Rectifier topology
Three-phase IGBT full wave, soft start, PFC, transformerless
OUTPUT
Power factor
0.9
Rated voltage
Single-phase 115 / 120 / 127 / 133 V(1) / Three-phase 3 x 200 / 3 x 208 / 3 x 220 / 3 x 230 (3F + N)
Dynamic accuracy
± 2% dynamic
Static accuracy
± 1% steady
Response time accuracy
20 ms for load steps 0% ÷ 100% and voltage drop up to -5%
Power (VA/W)
15000 / 13500
Total harmonic distortion (THDv) Linerar load
<0,5%
Total harmonic distortion (THDv) Non~linear load
<1,5% (EN-62040-3)
Synchronised frequency
50/60 Hz ±5 Hz (selectable)
Frequency
50 / 60 Hz
Frequency accuracy (battery mode)
50/60 Hz ±0,05%
Synchronous speed
From 1 Hz/s to 10 Hz/s (programmable)
Total performance in On-line mode
5÷30 kVA: 90%÷92% / 40÷100 kVA: 92%÷93%
Admissible overloads
125% for 10 min / 150% for 60 s / >150% for 20ms
MANUAL BYPASS
Protections
No breaks
STATIC BYPASS
Type and activation criteria
Solid state, controlled by microprocessor
Transfer times in Smart Eco-mode
4 ms (typical)
Transfer times in On-line
Nil
Transfer to bypass
Immediate, for overloads exceeding 150%
Retransfer
Automatic, after alarm deactivation
BATTERY
Battery type
Lead acid, sealed, maintenance free
Charging voltage regulation
Batt-Watch
COMMUNICATION
Ports
1 x RS232/RS485 + 1xUSB,with Modbus protocol
Relay interface
4 x AC failure, bypass, low battery and general
Intelligent slot
1, for SNMP
Monitoring software
Viewpower / UPSMAN
Backlit LCD display
Display LCD, LEDs y teclado
GENERAL
Operating temperature
0º C ÷ +40º C
Relative humidity
Up to 95%, non-condensing
Maxium operating altitude
2,400 masl
Acoustic noise at 1 metre
<52 dB(A)(2)
STANDARDS
Safety
EN-IEC 62040-1
Electromagnetic compatibility (EMC)
EN-62040-2
Operation
VFI-SS-11 (EN-62040-3)
Corporate cerification
ISO 9001, ISO 14001, ISO 45001
DIMENSIONS
Depth (mm)
775
Width (mm)
450
Height (mm)
1100
WEIGHT
Weight (kg)
237
(1) Up to 30 kVA.
(2) <65 dB(A) for 40 to 60 kVA models / <70 dB(A) for 80 to 100 kVA models
View distributor
Select Region and Country/Province to view Distributors
Accessories
Communications
AS-400 GX5 CON_R_AUX4
Relay interface for configuring inputs/outputs and switching contacts as required, up to 4 inputs/outputs.
Code: 663AA002213
EAN: 8436035929450
CS141 SENSOR CABLE
SNMP Card adapter cable for temperature and humidity sensor.
Code: 663AA002270
EAN: 8436584876298
MODEM GSM4G SMS BOX CS141-6 GX
GSM modem with an additional safety measure whereby coordinators and responsible technicians receive an SMS immediately if a fault occurs in the UPS system.
Code: 663AA002264
EAN: 8436584875406
NIMBUS ROUTER 4G
Device that uses 4G mobile networks to provide Internet connection via WiFi or Ethernet.
Code: 663AA002241
EAN: 8436584876281
NIMBUS SNMP Card
Nimbus Ethernet adapter / SNMP web adapter. Connection to the Salicru cloud (IoT - MQTT). Modbus TCP and RS232 protocol. SNMP V2. Shutdown of servers, via RCCMD software.
Code: 663AA002223
EAN: 8436584876274
SENSORMANAGER II CS141/CS121
Control unit allowing the connection of analogue and digital sensors for strategic room monitoring. 8 analogue inputs, 4 digital inputs and 4 digital outputs.
Code: 663AA002220
EAN: 8436584876267
SNMP Card GX5 CS141BSC-6
Ethernet adapter / SNMP web adapter. Modbus TCP protocol. SNMP V2 and V3. Shutdown of servers, by means of RCCMD software.
Code: 663AA002254
EAN: 8436584874270
SNMP RTH BOX GX5 CS141LM-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS485 protocol. SNMP V2 and V3. Outdoor location. Shutdown of servers, by means of RCCMD software. Connection with sensors and actuators.
Code: 663AA002260
EAN: 8436584875550
SNMP RTH CARD GX5 CS141SCM-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS485 protocol. SNMP V2 and V3. Shutdown of servers, via RCCMD software. Connection with sensors and actuators.
Code: 663AA002265
EAN: 8436584874881
SNMP TH BOX GX5 CS141-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS232 protocol. SNMP V2 and V3. Outdoor location. Shutdown of servers, via RCCMD software. Connection with sensors and actuators.
Code: 663AA002256
EAN: 8436584875536
SNMPTH CARD GX5 CS141SC-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS232 protocol. SNMP V2 and V3. Shutdown of servers, via RCCMD software. Connection with sensors and actuators.
Code: 663AA002259
EAN: 8436584875543
Software RCCMD
Application that allows the simultaneous and safe shutdown of different servers remotely. Communication via SNMP.
Code: 663AA002119
EAN: 8436584875246
SOFTWARE UNMS II-150
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 150 licenses.
Code: 663AA002141
EAN: 8436584876236
SOFTWARE UNMS II-200
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 200 licences.
Code: 663AA002261
EAN: 8436584874577
SOFTWARE UNMS II-25
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 25 licenses.
Code: 663AA002139
EAN: 8436584870388
SOFTWARE UNMS II-50
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 50 licenses.
Code: 663AA002140
EAN: 8436584876229
SOFTWARE UNMS II-9
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 9 licenses.
Code: 663AA002138
EAN: 8436035923212
Software UPSMAN
Application that allows simultaneous and safe shutdown of computers that are directly connected to the UPS via USB or serial network port.
Code: 663AA002123
EAN: 8436584876212
SOFTWARE VIEWPOWER
Viewpower is an advanced UPS management and administration software. It allows remote monitoring and remote management of one to several UPS in a network environment, either LAN or Internet. Downloadable via web.
Code: 663AA999998
T GX Sensor
Temperature sensor (range -25º C to +100º C). Compatible SNMP Card adapter required.
Code: 663AA002129
EAN: 8436035923953
T+H GX Sensor
Temperature sensor (range -25º C to +100º C) and relative humidity (range 0% to 100%). SNMP compatible SNMP Card adapter required
Code: 663AA002128
EAN: 8436035923946
Generic
BM-CUBE3+ A L-P-15-1/1
External Manual Bypass for SLC CUBE3+ A 15 kVA series equipment with single-phase input and output configuration. Allows maintenance to be carried out without interrupting the power supply to the protected equipment.
Code: 681OP000240
BM-CUBE3+ A MB-P-15-1/2
External Manual Bypass for SLC CUBE3+ A 15 kVA series equipment with single-phase input and three-phase output configuration. Allows maintenance to be carried out without interrupting the power supply to the protected equipment.
Code: 681OP000218
BM-CUBE3+ A NB-P-15-2/1
External Manual Bypass for SLC CUBE3+ A 15 kVA series equipment with three-phase input and single-phase output configuration. Allows maintenance to be carried out without interrupting the power supply to the protected equipment.
Code: 681OP000194
BM-CUBE3+ A P-15-2/2
External Manual Bypass for SLC CUBE3+ A 15 kVA series equipment with single-phase input and output configuration. Allows maintenance to be carried out without interrupting the power supply to the protected equipment.
Code: 681OP000122
EAN: BM-CUBE3+ P-15-2/2
CAB SLC BZ192 DB9M/DB9H 1.8m
Communication extension cable, DB9M/DB9H connectors, 1.8m length
Code: 663AC000005
CAB SLC BZ192 DB9M/DB9H 10m
Communication extension cable, DB9M/DB9H connectors, 10 m long
Code: 663AC000006
CAB SLC BZ192 DB9M/DB9H 3m
Communication extension cable, DB9M/DB9H connectors, 3m length
Code: 663AC000004
CAB SLC BZ192 DB9M/DB9H 5m
Communications extension cable, DB9M/DB9H connectors, 5m length
Code: 663AC000003
CABLE PARALELO CUBE3+
Communication cables required to manage the parallel system of two devices. One cable is required for each device that forms the parallel system. 5 metres long
Code: 663AC000075
Downloads
Documents
Data sheet
Catalogues
Manuals
Certificates & Declarations
Instructions
Software
VIEWPOWER HTML
Windows
installViewPower_Windows - 109MB Download
Software questions about SLC-15-CUBE3+ A?
Request information about SLC-15-CUBE3+ A
Welcome to Salicru. Select country/language
Argentina Español
Bolivia Español
Brazil Português
Caribbean Islands English
Chile Español
Colombia Español
Costa Rica Español
Cuba Español
Dominican Republic Español
Ecuador Español
El Salvador Español
Guatemala Español
Mexico Español
Nicaragua Español
Panama Español
Paraguay Español
Peru Español
United States English
Uruguay Español
Venezuela Español
extralarge
large
tablet
mobile
We use proprietary and third-party cookies to keep track of how our website is used and to be able to improve it,
adapt the content to your tastes and personalise our advertising, marketing and social media posts.
Click on the corresponding buttons to accept all of them, reject them or configure your settings.
Please see our Cookie Policy for more information.
















MONTAWEB.com