SLC-40-CUBE4
Specifications
Technical specifications
TECHNOLOGY
On-line, double conversion, HF, DSP control
INPUT
Voltage
3 × 380 / 3 × 400 / 3 × 415 V (3F + N)
Voltage range
7,5÷20 kVA: 110 ÷ 300 V (F-N) / 30÷80 kVA: 115 ÷ 265 V (F-N)
Rated frequency
50 / 60 Hz
Frequency range
7,5 ÷ 20kVA: 40 ÷ 70Hz (1) / 30 ÷ 80kVA: 45 ÷ 65Hz
Total harmonic distortion (THDi)
7,5÷20 kVA: <4% / 30÷80 kVA: <3%
Power factor
7.5÷20 kVA: ≥0.99 / 30÷80 kVA: 1 from 10% load
Rectifier topology
Three-phase IGBT full wave, soft start, PFC, transformerless
OUTPUT
Power factor
1
Voltage
3 × 380 / 3 × 400 / 3 × 415 V (3F + N)
Dynamic accuracy
±10%
Static accuracy
7,5÷20 kVA: ±1% / 30÷80 kVA: ±0,5%
Power (VA/W)
40000 / 40000
Synchronised frequency
50/60 Hz ±5 Hz (selectable)
Frequency
50 / 60 Hz
Frequency accuracy (battery mode)
50/60 Hz ±0,05%
Eco-mode performance
hasta 98,9%
Total performance in On-line mode
>96% (2)
Admissible overloads
7.5 ÷ 20 kVA: 110% 60 min / 110~125% 10 min / 125~150% 60 s / >150% 1 s 30 ÷ 80 kVA: 125% 10 min / 125~135% 5 min / 135~150% 60 s / >150% immediate
Crest factor
3 a 1
MANUAL BYPASS
Protections
Uninterrupted
STATIC BYPASS
Type and activation criteria
Solid state
Transfer times in Smart Eco-mode
<10 ms
Transfer to bypass
Immediate, for overloads exceeding 150%
Retransfer
Automatic, after alarm deactivation
BATTERY
Battery type
Pb-Ca, VRLA, lead acid, gel, Ni-Cd, Li-Ion
Charging voltage regulation
Batt-Watch
COMMUNICATION
Ports
1xRS232/485 + 1xUSB
Relay interface
7.5÷20 kVA: 6 relays / 30÷80 kVA: 4 relays (programmable)
Intelligent slot
NIMBUS, SNMP, RS232, RS485, USB, AS400 or remote battery temperature(3)
Monitoring software
CUBE4 Explorer
Backlit LCD display
5” colour touch screen
GENERAL
Operating temperature
0º C ÷ +40º C (3)
Relative humidity
Up to 95%, non-condensing
Maxium operating altitude
2,400 masl (4)
Acoustic noise at 1 metre
7,5÷20 kVA: <59 dB / 30÷40 kVA: <54 dB / 60÷80 kVA: <61,5 dB
SYSTEMS
Maximum no. parallel systems
No
STANDARDS
Safety
IEC/EN 62040-1
Electromagnetic compatibility (EMC)
IEC/EN 62040-2 C3
Operation
VFI-SS-11 (EN-62040-3)
Corporate cerification
ISO 9001, ISO 14001, ISO 45001
DIMENSIONS
Depth (mm)
910
Width (mm)
380
Height (mm)
1045
WEIGHT
Weight (kg)
334
(1) 1/1 options with power derating and 3/1 (under request)
(2) According to the selected operating mode
(3) For models 7,5-20 kVA = 1 Slot / For models 30-80 kVA = 2 Slots
(4) Up to 55ºC with power derating
(5) Power degradation for temperature altitudes, up to a maximum of 5,000 masl
3D
View distributor
Select Region and Country/Province to view Distributors
Accessories
Communications
AS-400 GX5 CON_R_AUX4
Relay interface for configuring inputs/outputs and switching contacts as required, up to 4 inputs/outputs.
Code: 663AA002213
EAN: 8436035929450
CS141 SENSOR CABLE
SNMP Card adapter cable for temperature and humidity sensor.
Code: 663AA002270
EAN: 8436584876298
MODEM GSM4G SMS BOX CS141-6 GX
GSM modem with an additional safety measure whereby coordinators and responsible technicians receive an SMS immediately if a fault occurs in the UPS system.
Code: 663AA002264
EAN: 8436584875406
NIMBUS AS Card DB9 RT2
Nimbus AS400 board potential free contacts and DB9 connector.
Code: 663AA002231
EAN: 8436584870883
NIMBUS AS400 Card
Nimbus AS400 card with potential-free contacts.
Code: 663AA002222
EAN: 8436584870869
NIMBUS ROUTER 4G
Device that uses 4G mobile networks to provide Internet connection via WiFi or Ethernet.
Code: 663AA002241
EAN: 8436584876281
NIMBUS2 Mini SNMP Card
Nimbus2 Ethernet / SNMP web adapter. Mini card format. Connection to the Salicru cloud (IoT - MQTT). Modbus TCP and RS232 protocol. SNMP V2. Shutdown of servers, by means of RCCMD software.
Code: 663AA002286
EAN: 8436584872856
RS-485 MODBUS CARD
Nimbus RS485 card with MODBUS protocol.
Code: 697OP000002
EAN: 8436035924127
SENSORMANAGER II CS141/CS121
Control unit allowing the connection of analogue and digital sensors for strategic room monitoring. 8 analogue inputs, 4 digital inputs and 4 digital outputs.
Code: 663AA002220
EAN: 8436584876267
SNMP Card GX5S CS141MINI-6
Ethernet adapter / SNMP web adapter. Mini card format. Modbus TCP and RS232 protocol. SNMP V2 and V3. Shutdown of servers, via RCCMD software.
Code: 663AA002252
EAN: 8436584873853
SNMP RTH BOX GX5 CS141LM-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS485 protocol. SNMP V2 and V3. Outdoor location. Shutdown of servers, by means of RCCMD software. Connection with sensors and actuators.
Code: 663AA002260
EAN: 8436584875550
SNMP TH BOX GX5 CS141-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS232 protocol. SNMP V2 and V3. Outdoor location. Shutdown of servers, via RCCMD software. Connection with sensors and actuators.
Code: 663AA002256
EAN: 8436584875536
Software RCCMD
Application that allows the simultaneous and safe shutdown of different servers remotely. Communication via SNMP.
Code: 663AA002119
EAN: 8436584875246
SOFTWARE UNMS II-150
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 150 licenses.
Code: 663AA002141
EAN: 8436584876236
SOFTWARE UNMS II-200
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 200 licences.
Code: 663AA002261
EAN: 8436584874577
SOFTWARE UNMS II-25
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 25 licenses.
Code: 663AA002139
EAN: 8436584870388
SOFTWARE UNMS II-50
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 50 licenses.
Code: 663AA002140
EAN: 8436584876229
SOFTWARE UNMS II-9
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 9 licenses.
Code: 663AA002138
EAN: 8436035923212
Software UPSMAN
Application that allows simultaneous and safe shutdown of computers that are directly connected to the UPS via USB or serial network port.
Code: 663AA002123
EAN: 8436584876212
SOFTWARE VIEWPOWER
Viewpower is an advanced UPS management and administration software. It allows remote monitoring and remote management of one to several UPS in a network environment, either LAN or Internet. Downloadable via web.
Code: 663AA999998
T GX Sensor
Temperature sensor (range -25º C to +100º C). Compatible SNMP Card adapter required.
Code: 663AA002129
EAN: 8436035923953
T+H GX Sensor
Temperature sensor (range -25º C to +100º C) and relative humidity (range 0% to 100%). SNMP compatible SNMP Card adapter required
Code: 663AA002128
EAN: 8436035923946
Generic
BM-CUBE4-P-40-4/4
External Manual Bypass for SLC CUBE4 series equipment of 40 kVA with three-phase input and output configuration. Allows maintenance to be carried out without interrupting the power supply to the protected equipment.
Code: 6B3OP000006
CAB SLC BZ192 DB9M/DB9H 1.8m
Communication extension cable, DB9M/DB9H connectors, 1.8m length
Code: 663AC000005
CAB SLC BZ192 DB9M/DB9H 10m
Communication extension cable, DB9M/DB9H connectors, 10 m long
Code: 663AC000006
CAB SLC BZ192 DB9M/DB9H 3m
Communication extension cable, DB9M/DB9H connectors, 3m length
Code: 663AC000004
CAB SLC BZ192 DB9M/DB9H 5m
Communications extension cable, DB9M/DB9H connectors, 5m length
Code: 663AC000003
CAB SLC BZ193 DB9M/DB9H 1.8m
Communications extension cable, DB9M/DB9H connectors, 1.8 m long
Code: 663AC000014
EAN: CABLE DB9 M/H 2M VLCP52010I20
CAB SLC BZ193 DB9M/DB9H 3m
Communications extension cable, DB9M/DB9H connectors, 3 m long
Code: 663AC000008
EAN: CABLE DB9 M/H 3M CX0403
CAB SLC BZ193 DB9M/DB9H 5m
Communications extension cable, DB9M/DB9H connectors, 5 m long
Code: 663AC000007
EAN: CABLE DB9 M/H 5M CS68
Autonomy
Autonomy curves
SLC-40-CUBE4 and SLC-40-CUBE4 B1
|
|
SLC-40-CUBE4
|
|
|
SLC-40-CUBE4 (6B3AC000002)
|
|
|
SLC-40-CUBE4 B1 + 1 x MOD BAT CUBE4 (6B3BT000015)
|
|
|
SLC-40-CUBE4 B1 (6B3AC000008) + 1 x MOD BAT CUBE4 (6B3BT000016)
|
|
|
SLC-40-CUBE4 B1 + 1 x MOD BAT CUBE4 (6B3BT000017)
|
|
|
SLC-40-CUBE4 B1 + 1 x MOD BAT CUBE4 (6B3BT000018)
|
|
|
SLC-40-CUBE4 B1 + 2 x MOD BAT CUBE4 (6B3BT000019)
|
Downloads
Documents
Data sheet
Catalogues
Manuals
Nimbus connectivity manual ETHERNET/SNMP/NIMBUS CLOUD NETWORK CARDS / AS400
Certificates & Declarations
Instructions
Software
VIEWPOWER HTML
Windows
installViewPower_Windows - 109MB Download
Software questions about SLC-40-CUBE4?
Request information about SLC-40-CUBE4
Welcome to Salicru. Select country/language
Australia English
Bangladesh English
Camboya English
China English
India English
Indonesia English
Japan English
Kazakhstan English
Laos English
Malaysia English
Myanmar English
New Zealand English
Pakistan English
Philippines English
Singapore English
South Korea English
Sri Lanka English
Taiwan English
Thailand English
Vietnam English
extralarge
large
tablet
mobile
We use proprietary and third-party cookies to keep track of how our website is used and to be able to improve it,
adapt the content to your tastes and personalise our advertising, marketing and social media posts.
Click on the corresponding buttons to accept all of them, reject them or configure your settings.
Please see our Cookie Policy for more information.

















MONTAWEB.com