UPS RECOMMENDER
UPS RECOMMENDER
 
General Catalogue (American Voltage)
 
SPS NET2
SPS NET2
 
General Catalogue (American Voltage)
 
Variable frequency drives
Variable frequency drives
 
General Catalogue (American Voltage)
 
Photovoltaic inverters
Photovoltaic inverters
 
General Catalogue (American Voltage)
 
Stabilisers
Stabilisers
 
General Catalogue (American Voltage)
 
DC Systems
DC Systems
 
General Catalogue (American Voltage)
 
Transformers
Transformers
 
General Catalogue (American Voltage)
Domestic
 
SPS NET2
SPS NET2
 
General Catalogue (American Voltage)
Sales Channels
 
Contact
Contact
 
General Catalogue (American Voltage)
Support
 
Maintenance contracts
Maintenance contracts
 
General Catalogue (American Voltage)

Questions about product

SPS ADVANCE RT2
Line-interactive sine-wave tower/rack UPS 800 VA to 3000 VA
Effective protection for entry-level servers and IT equipment
Battery backup time much shorter than expected.

Possible cause: Batteries not fully charged.

Solution: Charge batteries for at least 8 hours and then check their charge level. If problem persists, contact distributor or seller or, failing that, our TSS.

 

Possible cause: Batteries defective.

Solution: Contact distributor or seller or, failing that, our TSS for battery replacement.

When connecting UPS to mains, display does not illuminate nor show any indications

Possible cause: No voltage at input.

Solution: Check for mains voltage.

 

Possible cause: Input power cables badly connected.

Solution: Check input power cables firmly connected to mains and UPS.

 

Possible cause: Input cable connected to IEC output connector on UPS.

Solution: Correctly connect input cable to respective IEC connector.

Code: 14

Possible cause: UPS turns off automatically due to short circuit at output.

Solution: Check output wiring and that connected loads not short-circuited.

Code: 27

Possible cause: Voltage of batteries too high or charger faulty.

Solution: Contact distributor or seller or, failing that, our TSS.

Code: 28

Possible cause: Voltage of batteries too low or charger faulty.

Solution: Contact distributor or seller or, failing that, our TSS.

Code: 43

Possible cause: The UPS turns off automatically due to overload at output.

Solution: Disconnect the excess loads from the output sockets and restart it.

Code: 45

Possible cause: Charger does not provide output and battery voltage less than 10 V per element.

Solution: Disconnect excess load from output sockets and restart device.

Code: EP

Possible cause: EPO (emergency power off) function activated.

Solution: Close EPO signal circuit (fit connector with jumper) to deactivate it.

Code: NC

Possible cause: Internal or external batteries badly connected.

Solution: Check all batteries properly connected.

Code: OL

Possible cause: UPS overloaded.

Solution: Disconnect excess load from UPS output sockets.

 

Possible cause: The UPS is overloaded and connected loads are powered directly from the mains through the Bypass.

Solution: Disconnect excess load from UPS output sockets.

 

Possible cause: After repetitive overloads, the UPS is locked in Bypass mode and connected loads are powered directly from the mains through the Bypass.

Solution: Disconnect the excess loads from the output sockets, shut down the device and restart it.

Code: SF

Possible cause: Neutral to earth fault detection. Phase and neutral input cables inverted.

Solution: Disconnect input plug from AC power socket and invert connection of phase and supply neutral (rotate plug 180º).

Codes: 01, 02, 03, 11, 12, 13 und 41

Possible cause: Internal fault in UPS.

Solution: Contact distributor or seller or, failing that, our TSS.

Barcelona Web Design: MontawebMONTAWEB.com
Welcome to Salicru. Select country/language
Argentina   Español
Bolivia   Español
Brazil   Português
Canada   Français   English
Caribbean Islands   English
Chile   Español
Colombia   Español
Costa Rica   Español
Cuba   Español
Dominican Republic   Español
Ecuador   Español
El Salvador   Español
Guatemala   Español
Mexico   Español
Nicaragua   Español
Panama   Español
Paraguay   Español
Peru   Español
United States   English
Uruguay   Español
Venezuela   Español
extralarge
large
tablet
mobile
We use proprietary and third-party cookies to keep track of how our website is used and to be able to improve it, adapt the content to your tastes and personalise our advertising, marketing and social media posts. Click on the corresponding buttons to accept all of them, reject them or configure your settings. Please see our Cookie Policy for more information.