SPS SOHO+ (red)
Line-interactive UPS 500 VA - 2200 VA with dual USB charger
Optimum electrical protection for office environments and systems
UPS working but alarm sounds continuously

Possible cause: Overload at output.

Solution: Turn off and disconnect UPS. Disconnect excess load and reset input protection. Connect and turn on UPS.

When connecting UPS to mains, it does not start

Possible cause: On-Off button not pressed.

Solution: Press and hold down “On-Off” button for 2 seconds. Button surround illuminates white.

 

Possible cause: Input power cables badly connected.

Solution: Check input power cables firmly connected to mains and UPS.

 

Possible cause: Battery damaged.

Solution: Contact distributor or seller or, failing that, our TSS.

 

Possible cause: Mechanical problem.

Solution: Contact distributor or seller or, failing that, our TSS.

When turning on UPS, LED of “On-Off” button surround flashes and sounds a beep every 30 seconds

Possible cause: No voltage at input.

Solution: Check for mains voltage.

 

ossible cause: Input power cables badly connected.

Solution: Check input power cables firmly connected to mains and UPS.

Battery backup time much shorter than expected.

Possible cause: Batteries not fully charged.

Solution: Charge batteries for at least 8 hours and then check their charge level. If problem persists, contact distributor or seller or, failing that, our TSS.

 

Possible cause: Batteries defective.

Solution: Contact distributor or seller or, failing that, our TSS for battery replacement.

No output voltage

Possible cause: Input protection tripped by overload at output.

Solution: Disconnect load and reset input protection.

 

Possible cause: Battery discharged.

Solution: Charge batteries for at least 7 hours. If problem persists, contact distributor or seller or, failing that, our TSS.

 

Possible cause: UPS faulty.

Solution: Contact distributor or seller or, failing that, our TSS.

Power Panel software installed but does not run

Possible cause: USB cable not connected.

Solution: Connect USB cable between UPS and computer. Use cable supplied with UPS.

Barcelona Web Design: MontawebMONTAWEB.com
Welcome to Salicru. Select country/language
Argentina   Español
Bolivia   Español
Brazil   Português
Canada   Français   English
Caribbean Islands   English
Chile   Español
Colombia   Español
Costa Rica   Español
Cuba   Español
Dominican Republic   Español
Ecuador   Español
El Salvador   Español
Guatemala   Español
Mexico   Español
Nicaragua   Español
Panama   Español
Paraguay   Español
Peru   Español
United States   English
Uruguay   Español
Venezuela   Español
extralarge
large
tablet
mobile
We use proprietary and third-party cookies to keep track of how our website is used and to be able to improve it, adapt the content to your tastes and personalise our advertising, marketing and social media posts. Click on the corresponding buttons to accept all of them, reject them or configure your settings. Please see our Cookie Policy for more information.