SLC-20-CUBE3+
20 kVA three-phase Uninterruptible Power Supply System
Energy efficiency with superior electrical protection
Input voltage (V): 220 / 230 / 240 V - 3 x 380 / 3 x 400 / 3 x 415 V (3F + N)
Output voltage (V): 220 / 230 / 240 V - 3 x 380 / 3 x 400 / 3 x 415 V (3F + N)
Power (VA): 20000
Type: UPS Standard
Code: 681LA000342
Specifications
Technical specifications
TECHNOLOGY
On-line, double conversion, HF, DSP control
INPUT
Voltage
220 / 230 / 240 V - 3 x 380 / 3 x 400 / 3 x 415 V (3F + N)
Voltage range
+15% / -20% (configurable)
Rated frequency
50 / 60 Hz
Total harmonic distortion (THDi)
100% load: <1.5% / 50% load: <2.5% / 10% load: <6.0%
Power factor
1 from 10% load
Rectifier topology
Three-phase IGBT full wave, soft start, PFC, transformerless
OUTPUT
Power factor
0,9
Voltage
220 / 230 / 240 V - 3 x 380 / 3 x 400 / 3 x 415 V (3F + N)
Dynamic accuracy
± 2% dynamic
Static accuracy
± 1% steady
Response time accuracy
20 ms for load steps 0% ÷ 100% and voltage drop up to -5%
Power (VA/W)
20000 / 18000
Total harmonic distortion (THDv) Linerar load
<0.5%
Total harmonic distortion (THDv) Non~linear load
<1.5% (EN-62040-3)
Synchronised frequency
50/60 Hz ±5 Hz (selectable)
Frequency
50/60 Hz +/- 5 Hz (selectable)
Frequency accuracy (battery mode)
50/60 Hz ±0.05%
Synchronous speed
From 1 Hz/s to 10 Hz/s (programmable)
Eco-mode performance
96%
Total performance in On-line mode
7.5÷60 kVA: 92.0%÷93.0% / 80÷200 kVA: 94.0%÷95.0%
Admissible overloads
125% for 10 min / 150% for 60 s / >150% for 20ms
Crest factor
3,4 a 1
MANUAL BYPASS
Protections
No breaks
STATIC BYPASS
Type and activation criteria
Solid state, controlled by microprocessor
Transfer times in Smart Eco-mode
4 ms (typical)
Transfer times in On-line
Nil
Transfer to bypass
Immediate, for overloads exceeding 150%
Retransfer
Automatic, after alarm deactivation
BATTERY
Battery type
Lead acid, sealed, maintenance free
Charging voltage regulation
Batt-Watch
COMMUNICATION
Ports
1 x RS232/RS485 + 1xUSB,with Modbus protocol
Relay interface
4 x AC failure, bypass, low battery and general
Intelligent slot
1, for SNMP
Monitoring software
Viewpower / UPSMAN
Backlit LCD display
LCD display, LEDs and keyboard
GENERAL
Operating temperature
0º C ÷ +40º C
Relative humidity
Up to 95%, non-condensing
Maxium operating altitude
2,400 masl (3)
Acoustic noise at 1 metre
<52 dB(A)(4)
SYSTEMS
Maximum no. parallel systems
Yes, up to 4 units
IMPLEMENTATIONS
Nº Cabinets (Ups + BAT)
1 + 0
STANDARDS
Safety
EN-IEC 62040-1
Electromagnetic compatibility (EMC)
EN-62040-2
Operation
VFI-SS-11 (EN-62040-3)
Corporate cerification
ISO 9001, ISO 14001, ISO 45001
DIMENSIONS
Depth (mm)
775
Width (mm)
450
Height (mm)
1100
WEIGHT
Weight (kg)
233
(1) Up to 60 kVA. (2) Only for three-phase input / output models. FP = 0.8 for other configurations. (3) Power derating for higher altitudes up to 5000 masl. (4) <65 dB(A) for 80 to 120 kVA models / <70 dB(A) for 160 to 200 kVA models.
View distributor
Region
Select Region and Country/Province to view Distributors
Accessories
Communications
AS-400 GX5 CON_R_AUX4
Relay interface for configuring inputs/outputs and switching contacts as required, up to 4 inputs/outputs.
Code: 663AA002213
EAN: 8436035929450
CS141 SENSOR CABLE
SNMP Card adapter cable for temperature and humidity sensor.
Code: 663AA002270
EAN: 8436584876298
MODEM GSM4G SMS BOX CS141-6 GX
GSM modem with an additional safety measure whereby coordinators and responsible technicians receive an SMS immediately if a fault occurs in the UPS system.
Code: 663AA002264
EAN: 8436584875406
NIMBUS ROUTER 4G
Device that uses 4G mobile networks to provide Internet connection via WiFi or Ethernet.
Code: 663AA002241
EAN: 8436584876281
NIMBUS SNMP Card
Nimbus Ethernet adapter / SNMP web adapter. Connection to the Salicru cloud (IoT - MQTT). Modbus TCP and RS232 protocol. SNMP V2. Shutdown of servers, via RCCMD software.
Code: 663AA002223
EAN: 8436584876274
SENSORMANAGER II CS141/CS121
Control unit allowing the connection of analogue and digital sensors for strategic room monitoring. 8 analogue inputs, 4 digital inputs and 4 digital outputs.
Code: 663AA002220
EAN: 8436584876267
SNMP Card GX5 CS141BSC-6
Ethernet adapter / SNMP web adapter. Modbus TCP protocol. SNMP V2 and V3. Shutdown of servers, by means of RCCMD software.
Code: 663AA002254
EAN: 8436584874270
SNMP RTH BOX GX5 CS141LM-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS485 protocol. SNMP V2 and V3. Outdoor location. Shutdown of servers, by means of RCCMD software. Connection with sensors and actuators.
Code: 663AA002260
EAN: 8436584875550
SNMP RTH CARD GX5 CS141SCM-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS485 protocol. SNMP V2 and V3. Shutdown of servers, via RCCMD software. Connection with sensors and actuators.
Code: 663AA002265
EAN: 8436584874881
SNMP TH BOX GX5 CS141-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS232 protocol. SNMP V2 and V3. Outdoor location. Shutdown of servers, via RCCMD software. Connection with sensors and actuators.
Code: 663AA002256
EAN: 8436584875536
SNMPTH CARD GX5 CS141SC-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS232 protocol. SNMP V2 and V3. Shutdown of servers, via RCCMD software. Connection with sensors and actuators.
Code: 663AA002259
EAN: 8436584875543
Software RCCMD
Application that allows the simultaneous and safe shutdown of different servers remotely. Communication via SNMP.
Code: 663AA002119
EAN: 8436584875246
SOFTWARE UNMS II-150
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 150 licenses.
Code: 663AA002141
EAN: 8436584876236
SOFTWARE UNMS II-200
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 200 licences.
Code: 663AA002261
EAN: 8436584874577
SOFTWARE UNMS II-25
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 25 licenses.
Code: 663AA002139
EAN: 8436584870388
SOFTWARE UNMS II-50
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 50 licenses.
Code: 663AA002140
EAN: 8436584876229
SOFTWARE UNMS II-9
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 9 licenses.
Code: 663AA002138
EAN: 8436035923212
Software UPSMAN
Application that allows simultaneous and safe shutdown of computers that are directly connected to the UPS via USB or serial network port.
Code: 663AA002123
EAN: 8436584876212
SOFTWARE VIEWPOWER
Viewpower is an advanced UPS management and administration software. It allows remote monitoring and remote management of one to several UPS in a network environment, either LAN or Internet. Downloadable via web.
Code: 663AA999998
T GX Sensor
Temperature sensor (range -25º C to +100º C). Compatible SNMP Card adapter required.
Code: 663AA002129
EAN: 8436035923953
T+H GX Sensor
Temperature sensor (range -25º C to +100º C) and relative humidity (range 0% to 100%). SNMP compatible SNMP Card adapter required
Code: 663AA002128
EAN: 8436035923946
Generic
BATT MOD for CUBE3+ 0/2x62 7/9/12Ah 7,5-20KVA
Empty Battery Module to house 2 branches of 62 batteries of 7/9/12 Ah for SLC CUBE3+ series equipment from 7.5 to 20 kVA
Code: 681BU000325
BATT MOD for CUBE3+ 0/62 24Ah 7,5-20KVA
Empty Battery Module to house 1 branch of 62 batteries of 24 Ah for SLC CUBE3+ series equipment from 7.5 to 20 kVA
Code: 681BU000341
BATT MOD for CUBE3+ 0/62 45Ah 7,5-20KVA
Empty Battery Module to house 1 branch of 62 batteries of 45 Ah for SLC CUBE3+ series equipment from 7.5 to 20 kVA
Code: 681BU000321
BM-CUBE3+ L-P-20-2/2
External Manual Bypass for SLC CUBE3+ 20 kVA series equipment with single-phase input and output configuration. Allows maintenance to be carried out without interrupting the power supply to the protected equipment.
Code: 681OP000227
BM-CUBE3+ MB-P-20-2/4
External Manual Bypass for SLC CUBE3+ 20 kVA series equipment with single-phase input and three-phase output configuration. Allows maintenance to be carried out without interrupting the power supply to the protected equipment.
Code: 681OP000205
BM-CUBE3+ NB-P-20-4/2
External Manual Bypass for SLC CUBE3+ 20 kVA series equipment with three-phase input and single-phase output configuration. Allows maintenance to be carried out without interrupting the power supply to the protected equipment.
Code: 681OP000094
EAN: BM-CUBE3+ NB-P-20-4/2
BM-CUBE3+ P-20-4/4
External Manual Bypass for SLC CUBE3+ 20 kVA series equipment three-phase input and output configuration. Allows maintenance to be carried out without interrupting the power supply to the protected equipment.
Code: 681OP000053
EAN: BM-CUBE3+ P-20-4/4
CAB SLC BZ192 DB9M/DB9H 1.8m
Communication extension cable, DB9M/DB9H connectors, 1.8m length
Code: 663AC000005
CAB SLC BZ192 DB9M/DB9H 10m
Communication extension cable, DB9M/DB9H connectors, 10 m long
Code: 663AC000006
CAB SLC BZ192 DB9M/DB9H 3m
Communication extension cable, DB9M/DB9H connectors, 3m length
Code: 663AC000004
CAB SLC BZ192 DB9M/DB9H 5m
Communications extension cable, DB9M/DB9H connectors, 5m length
Code: 663AC000003
CABLE PARALELO CUBE3+
Communication cables required to manage the parallel system of two devices. One cable is required for each device that forms the parallel system. 5 metres long
Code: 663AC000075
Autonomy
Autonomy curves
SLC 20 CUBE3+ and SLC 20 CUBE3+ B1
SLC-20-CUBE3+
SLC-20-CUBE3+ 62BS016
SLC-20-CUBE3+ B1+ 1 MOD BAT CUBE3+ 2x62BS015 32A (681BU000522)
SLC-20-CUBE3+ B1+ 1 MOD BAT CUBE3+ 2x62BS017 32A (681BU000524)
SLC-20-CUBE3+ B1+ 1 MOD BAT CUBE3+ 62BS020 32A (681BU000525)
Downloads
Documents
Data sheet
Data Sheet SLC CUBE3+
Catalogues
Product Catalogue SLC CUBE3+
General Catalogue
Manuals
Installation SLC CUBE3+ three phase in/out SLC CUBE3+
Installation SLC CUBE3+-B three phase in/out SLC CUBE3+
SLC CUBE3+ single-phase in/out installation SLC CUBE3+
SLC CUBE3+ -B single phase in/out installation SLC CUBE3+
Installation SLC CUBE3+ -B three-phase in/ single-phase out
Installation SLC CUBE3+ -B single-phase in/three-phase out
Manual SLC CUBE3+
Control panel with touch screen manual SLC CUBE3+
Bypass box manual
Manual Protocol Map - IN46701 SLC CUBE3+
USER'S MANUAL OPTIONS SLC CUBE3+
Product guide SLC CUBE3+
Quick unpacking guide SLC CUBE3+
Dimensional drawing SLC CUBE3+ 10-60 kVA SLC CUBE3+
Dimensional drawing SLC CUBE3+ 10-60 kVA SLC CUBE3+
Dimensional drawing SLC CUBE3+ B1 15-200 kVA SLC CUBE3+
Certificates & Declarations
Declaration of conformity SLC CUBE3+
Type Test Certificate SLC CUBE3+
ISO 45001 certificate
ISO 9001 certificate
ISO 14001 certificate
Instructions
End Of Life Instructions SLC CUBE3+
Safety instructions
Software
VIEWPOWER HTML
Windows
Windows
installViewPower_Windows - 109MB Download
Mac OS
Mac OS
ViewPowerHTML_MAC_x64_Intel. - 81.7MB Download
installViewPowerHTML_MAC_x64_Mchip - 79.1MB Download
Linux
Linux
ViewPowerHTML_Linux_x86_64 - 77MB Download
ViewPowerHTML_Linux_text_x86_64 - 116 MB Download
ViewPowerHTML_Linux_text_i386 - 77,9MB Download
ViewPowerHTML_Linux_i386 -77.3MB Download
Windows
Windows
ViewpowerHTML5 user's manual Download
Mac OS
Mac OS
ViewpowerHTML5 user's manual Download
Linux
Linux
ViewpowerHTML5 user's manual Download
Software questions about SLC-20-CUBE3+?
Request information about SLC-20-CUBE3+

To contact Salicru directly or request information about any of our products, please fill in the following details and press send.

Please enter your name
Please indicate the position
Please indicate the position
Please enter your email
Please enter your address
Please enter your post code
Please enter your town/city
Please enter your country
Please enter your enquiryRequired field
INFORMATION ON DATA PROTECTION OF SALICRU S.A.

Purposes: To send you information about our products, including by electronic means.

Legitimacy: Consent of the interested party. Recipients: No transfers of data to third parties are anticipated, except in the event of legal requirement.

Rights: You can withdraw your consent at any time, and exercise your rights of data access, rectification, erasure and other rights at rgpd@salicru.com, as explained in the Privacy Policy.

Additional information: You can find additional information by clicking on Legal Notice.

I wish to receive commercial information, including by electronic means.
   
Indicate if you want to receive the newsletter
Please read and accept the privacy policy
* Required field.
Barcelona Web Design: MontawebMONTAWEB.com
Welcome to Salicru. Select country/language
Algeria   Français
Angola   Português
Bahrain   English
Congo   Français
Côte d'Ivoire   Français
Egypt   English
Equatorial Guinea   Español   Português   Français
Iraq   English
Jordan   English
Kenya   English
Kuwait   English
Lebanon   English
Libya   English
Madagascar   Français
Mali   Français
Mauritania   Français
Morocco   Français
Niger   Français
Nigeria   English
Oman   English
Qatar   English
Reunion   Français
Saudi Arabia   English
Senegal   Français
South Africa   English
Syria   English
Tanzania   Français
Tunisia   Français   English
Turkey   English
Uganda   English
United Arab Emirates   English
extralarge
large
tablet
mobile
We use proprietary and third-party cookies to keep track of how our website is used and to be able to improve it, adapt the content to your tastes and personalise our advertising, marketing and social media posts. Click on the corresponding buttons to accept all of them, reject them or configure your settings. Please see our Cookie Policy for more information.