CF-7,5-CUBE3+ 60/50HZ
Frequency converter three-phase from 7,5 kVA
Energy efficiency with superior electrical protection
Power (VA): 7500
Input frequency: 60
Output frequency: 50
Code: 681LM000002
Specifications
Technical specifications
TECHNOLOGY
On-line, double conversion, HF, DSP control
INPUT
Voltage
3x380 / 3x400 / 3x415 V
Voltage range
+15% / -20% (configurable)
Rated frequency
50 / 60 Hz
Total harmonic distortion (THDi)
100% load: <1.5% / 50% load: <2.5% / 10% load: <6.0%
Power factor
1 from 10% load
Rectifier topology
Three-phase IGBT full wave, soft start, PFC, transformerless
OUTPUT
Power factor
0.9
Voltage
3 x 208 / 3 x 220 / 3 x 380 / 3 x 400 / 3 x 415 V (3F + N)
Dynamic accuracy
± 2% dynamic
Static accuracy
± 1% steady
Response time accuracy
20 ms for load steps 0% ÷ 100% and voltage drop up to -5%
Power (VA/W)
7500 / 6750
Total harmonic distortion (THDv) Linerar load
<0.5%
Total harmonic distortion (THDv) Non~linear load
<1.5% (EN-62040-3)
Frequency
50/60 Hz ±0.05%
Eco-mode performance
95%
Total performance in On-line mode
7.5÷60 kVA: 92.0%÷93.0% / 80÷200 kVA: 94.0%÷95.0%
Admissible overloads
125% for 10 min / 150% for 60 s / >150% for 20ms
Crest factor
3,4 a 1
COMMUNICATION
Ports
1 x RS232/RS485 + 1xUSB,with Modbus protocol
Relay interface
4 x AC failure, bypass, low battery and general
Intelligent slot
1, for SNMP
Monitoring software
For Windows, Linux and Mac
GENERAL
Operating temperature
0º C ÷ +40º C
Relative humidity
Up to 95%, non-condensing
Maxium operating altitude
2,400 masl (3)
Acoustic noise at 1 metre
52 dB(A)(2)
STANDARDS
Safety
EN-IEC 62040-1
Electromagnetic compatibility (EMC)
EN-62040-2
Corporate cerification
ISO 9001, ISO 14001, ISO 45001
DIMENSIONS
Depth (mm)
775
Width (mm)
450
Height (mm)
1100
WEIGHT
Weight (kg)
100
(1) Single-phase 120 / 127 V available up to 30 kVA inclusive and three-phase 3 x 208 / 3 x 220 V available up to 100 kVA inclusive. (2) <65 dB(A) for 80 to 120 kVA models / <70 dB(A) for 160 and 200 kVA models. (3) Power derating for higher altitudes up to 5000 masl.
View distributor
Region
Select Region and Country/Province to view Distributors
Accessories
Communications
AS-400 GX5 CON_R_AUX4
Relay interface for configuring inputs/outputs and switching contacts as required, up to 4 inputs/outputs.
Code: 663AA002213
EAN: 8436035929450
CS141 SENSOR CABLE
SNMP Card adapter cable for temperature and humidity sensor.
Code: 663AA002270
EAN: 8436584876298
MODEM GSM4G SMS BOX CS141-6 GX
GSM modem with an additional safety measure whereby coordinators and responsible technicians receive an SMS immediately if a fault occurs in the UPS system.
Code: 663AA002264
EAN: 8436584875406
NIMBUS ROUTER 4G
Device that uses 4G mobile networks to provide Internet connection via WiFi or Ethernet.
Code: 663AA002241
EAN: 8436584876281
NIMBUS SNMP Card
Nimbus Ethernet adapter / SNMP web adapter. Connection to the Salicru cloud (IoT - MQTT). Modbus TCP and RS232 protocol. SNMP V2. Shutdown of servers, via RCCMD software.
Code: 663AA002223
EAN: 8436584876274
SENSORMANAGER II CS141/CS121
Control unit allowing the connection of analogue and digital sensors for strategic room monitoring. 8 analogue inputs, 4 digital inputs and 4 digital outputs.
Code: 663AA002220
EAN: 8436584876267
SNMP Card GX5 CS141BSC-6
Ethernet adapter / SNMP web adapter. Modbus TCP protocol. SNMP V2 and V3. Shutdown of servers, by means of RCCMD software.
Code: 663AA002254
EAN: 8436584874270
SNMP RTH BOX GX5 CS141LM-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS485 protocol. SNMP V2 and V3. Outdoor location. Shutdown of servers, by means of RCCMD software. Connection with sensors and actuators.
Code: 663AA002260
EAN: 8436584875550
SNMP RTH CARD GX5 CS141SCM-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS485 protocol. SNMP V2 and V3. Shutdown of servers, via RCCMD software. Connection with sensors and actuators.
Code: 663AA002265
EAN: 8436584874881
SNMP TH BOX GX5 CS141-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS232 protocol. SNMP V2 and V3. Outdoor location. Shutdown of servers, via RCCMD software. Connection with sensors and actuators.
Code: 663AA002256
EAN: 8436584875536
SNMPTH CARD GX5 CS141SC-6
Ethernet adapter / SNMP web adapter. Modbus TCP and RS232 protocol. SNMP V2 and V3. Shutdown of servers, via RCCMD software. Connection with sensors and actuators.
Code: 663AA002259
EAN: 8436584875543
Software RCCMD
Application that allows the simultaneous and safe shutdown of different servers remotely. Communication via SNMP.
Code: 663AA002119
EAN: 8436584875246
SOFTWARE UNMS II-150
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 150 licenses.
Code: 663AA002141
EAN: 8436584876236
SOFTWARE UNMS II-200
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 200 licences.
Code: 663AA002261
EAN: 8436584874577
SOFTWARE UNMS II-25
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 25 licenses.
Code: 663AA002139
EAN: 8436584870388
SOFTWARE UNMS II-50
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 50 licenses.
Code: 663AA002140
EAN: 8436584876229
SOFTWARE UNMS II-9
Network management system that can actively manage monitored UPS and external components and execute automatic actions. Up to 9 licenses.
Code: 663AA002138
EAN: 8436035923212
Software UPSMAN
Application that allows simultaneous and safe shutdown of computers that are directly connected to the UPS via USB or serial network port.
Code: 663AA002123
EAN: 8436584876212
SOFTWARE VIEWPOWER
Viewpower is an advanced UPS management and administration software. It allows remote monitoring and remote management of one to several UPS in a network environment, either LAN or Internet. Downloadable via web.
Code: 663AA999998
T GX Sensor
Temperature sensor (range -25º C to +100º C). Compatible SNMP Card adapter required.
Code: 663AA002129
EAN: 8436035923953
T+H GX Sensor
Temperature sensor (range -25º C to +100º C) and relative humidity (range 0% to 100%). SNMP compatible SNMP Card adapter required
Code: 663AA002128
EAN: 8436035923946
Generic
CABLE PARALELO CUBE3+
Communication cables required to manage the parallel system of two devices. One cable is required for each device that forms the parallel system. 5 metres long
Code: 663AC000075
Empty Batt Mod 1x62 of 24 Ah for SLC CUBE3+
Battery cabinet without batteries prepared for installation 1 branch of 62 batteries of 24 Ah for UPS models series SLC CUBE3+.
Code: O6819999998
Empty Batt Mod 1x62 of 45 Ah for SLC CUBE3+
Battery cabinet without batteries prepared for installation 1 branch of 62 batteries of 45 Ah for UPS models series SLC CUBE3+.
Code: O6819999997
Empty Batt Mod 2x62 of 7 / 9 / 12 Ah for SLC CUBE3+
Battery cabinet without batteries prepared for the installation of 2 branches of 62 7 / 9 / 12 Ah batteries for UPS models SLC CUBE3+ series.
Code: O6819999999
Downloads
Documents
Data sheet
Data Sheet CF CUBE3+
Catalogues
General Catalogue
Certificates & Declarations
Declaration of conformity SLC CUBE3+
ISO 45001 certificate
ISO 9001 certificate
ISO 14001 certificate
Instructions
Safety instructions
Request information about CF-7,5-CUBE3+ 60/50HZ

To contact Salicru directly or request information about any of our products, please fill in the following details and press send.

Please enter your name
Please indicate the position
Please indicate the position
Please enter your email
Please enter your address
Please enter your post code
Please enter your town/city
Please enter your country
Please enter your enquiryRequired field
INFORMATION ON DATA PROTECTION OF SALICRU S.A.

Purposes: To send you information about our products, including by electronic means.

Legitimacy: Consent of the interested party. Recipients: No transfers of data to third parties are anticipated, except in the event of legal requirement.

Rights: You can withdraw your consent at any time, and exercise your rights of data access, rectification, erasure and other rights at rgpd@salicru.com, as explained in the Privacy Policy.

Additional information: You can find additional information by clicking on Legal Notice.

I wish to receive commercial information, including by electronic means.
   
Indicate if you want to receive the newsletter
Please read and accept the privacy policy
* Required field.
Barcelona Web Design: MontawebMONTAWEB.com
Welcome to Salicru. Select country/language
Andorra   Català   Español
Armenia   English
Austria   Deutsch   English
Belarus   English
Belgium   Français   English
Bulgaria   English
Croatia   English
Cyprus   English
Czech Republic   English
Denmark   English
Estonia   English
Finland   English
France   Français
Georgia   English
Germany   Deutsch   English
Greece   English
Hungary   English
Ireland   English
Italy   English
Latvia   English
Lithuania   English
Luxembourg   Français   Deutsch
Malta   English
Netherlands   English
Norway   English
Poland   English
Portugal   Português
Romania   English
Russia   English
Serbia   English
Slovakia   English
Spain   Español   Català
Sweden   English
Switzerland   Français   Deutsch   English
Ukraine   English
United Kingdom   English
extralarge
large
tablet
mobile
We use proprietary and third-party cookies to keep track of how our website is used and to be able to improve it, adapt the content to your tastes and personalise our advertising, marketing and social media posts. Click on the corresponding buttons to accept all of them, reject them or configure your settings. Please see our Cookie Policy for more information.