SLC-#/9-ADAPT2 54 A
Modular three-phase Uninterruptible Power Systems of up to 54000 VA
Modularity, optimisation and efficiency in electrical safety for data centres
Module power (VA / W): 9.000 / 9.000
No. Modules: 1 to 6
Input voltage (V): 3x 208 / 220 V (3F + N)
Output voltage (V): 3x 208 / 220 V (3F + N)
System power (VA/W): 54000 / 54000
Code: 694OQ000079
Specifications
Technical specifications
TECHNOLOGY
On-line double-conversion, HF, DSP control
PHYSICAL
Module/System
Sistema
No. Modules (#)
1 to 6
INPUT
Rated three-phase voltage (3P+ N + E)
3 x 208 / 220 V
Voltage range
-40% +25% (Depending on charge)(1)
Rated frequency
50 / 60 Hz
Frequency range
40 - 70 Hz
Total harmonic distortion (THDi)
≤3%
Power factor
>0.99
OUTPUT
Power factor
1
Rated three-phase voltage (3P + N + E)
3 x 208 / 220 V
Static accuracy
±1%
Power (VA/W)
54000 / 54000
Maximum power (VA/W)
54000 / 54000
Total harmonic distortion (THDv) Linerar load
<1%
Total harmonic distortion (THDv) Non~linear load
<5%
Frequency
50 / 60 Hz
Module performance (On-line)
> 96%
Performance in Smart Eco-mode
99%
Admissible overloads
<110% for 1 hour / <125% for 10 min / <150% for 1 min / >150% for 200 ms
Crest factor
3:1
MANUAL BYPASS
Protections
Uninterrupted (optional)(2)
STATIC BYPASS
Type
Static thyristor
Transfer time
0 ms
Admissible overloads
≤110% constant / ≤130% for 1 hour / ≤150% for 1 minute / >150% for 5 seconds
BATTERY
Battery type
Pb-Ca, VRLA, lead acid, gel, Ni-Cd, Li-Ion
Charging voltage regulation
Batt-watch
Charger maximum power (W)
20% of total system power
COMMUNICATION
Display
7” touchscreen, LEDs and keypad
Ports
RS-232, RS-485 and relays
Intelligent slot
1 x Nimbus SNMP/1 x Nimbus extended relays
GENERAL
Operating temperature
0º C ÷ +55º C (3)
Relative humidity
Up to 95%, non-condensing
Maxium operating altitude
2,400 masl(4)
Acoustic noise at 1 metre
<54 dB(A) (According to number of modules)
STANDARDS
Safety
EN-IEC 62040-1
Electromagnetic compatibility (EMC)
EN-IEC 62040-2
Operation
VFI-SS-11 (EN-62040-3)
Corporate cerification
ISO 9001, ISO 14001, ISO 45001
DIMENSIONS
Depth (mm)
751
Width (mm)
485
Height (mm)
1033
WEIGHT
Weight (kg)
101

(1) Linear % load derating from -20% to -40%.

(2) Not included in subracks. Excellent for cabinet systems.

(3) Power derating for higher altitudes up to +40ºC.

(4) Power degradation for higher altitudes, up to a maximum of 5,000 masl.

Video
View distributor
Region
Select Region and Country/Province to view Distributors
Downloads
Documents
Data sheet
Data Sheet SLC ADAPT2 A
Catalogues
General Catalogue (American Voltage)
Manuals
Bypass box manual
SLC ADAPT2
Certificates & Declarations
ISO 45001 certificate
ISO 9001 certificate
ISO 14001 certificate
Instructions
Safety instructions
Request information about SLC-#/9-ADAPT2 54 A

To contact Salicru directly or request information about any of our products, please fill in the following details and press send.

Please enter your name
Please indicate the position
Please indicate the position
Please enter your email
Please enter your address
Please enter your post code
Please enter your town/city
Please enter your country
Please enter your enquiryRequired field
INFORMATION ON DATA PROTECTION OF SALICRU S.A.

Purposes: To send you information about our products, including by electronic means.

Legitimacy: Consent of the interested party. Recipients: No transfers of data to third parties are anticipated, except in the event of legal requirement.

Rights: You can withdraw your consent at any time, and exercise your rights of data access, rectification, erasure and other rights at rgpd@salicru.com, as explained in the Privacy Policy.

Additional information: You can find additional information by clicking on Legal Notice.

I wish to receive commercial information, including by electronic means.
   
Indicate if you want to receive the newsletter
Please read and accept the privacy policy
* Required field.
Barcelona Web Design: MontawebMONTAWEB.com
Welcome to Salicru. Select country/language
Argentina   Español
Bolivia   Español
Brazil   Português
Canada   Français   English
Caribbean Islands   English
Chile   Español
Colombia   Español
Costa Rica   Español
Cuba   Español
Dominican Republic   Español
Ecuador   Español
El Salvador   Español
Guatemala   Español
Mexico   Español
Nicaragua   Español
Panama   Español
Paraguay   Español
Peru   Español
United States   English
Uruguay   Español
Venezuela   Español
extralarge
large
tablet
mobile
We use proprietary and third-party cookies to keep track of how our website is used and to be able to improve it, adapt the content to your tastes and personalise our advertising, marketing and social media posts. Click on the corresponding buttons to accept all of them, reject them or configure your settings. Please see our Cookie Policy for more information.