Line-interactive APFC multi-socket UPS 650 VA, 850 VA and 1000 VA
Multi-plug solution to guarantee power during unforeseen events.
The SPS does not get going

Solution: With the equipment running, press the power button to stop. After 10 seconds, press the button again to start it again.

  • Possible cause: The SPS is not connected to an AC outlet.

Solution: Connect it to a base with a voltage of 220... 240 V 50/60 Hz.

  • Possible cause: The battery has reached the end of its useful life.

Solution: Contact the distributor or seller and failing that, the S.S.T.

  • Possible cause: Mechanical or electronic problem.

Solution: Contact the distributor or seller and failing that, the S.S.T.

SPS outlets do not supply voltage
  • Possible cause: The "master-slave" mode is activated.

Solution: Review point 5.5 of the user manual to modify the "master-slave" configuration.

 

  • Possible cause: The thermal has tripped, due to an overload

Solution: If an overload is detected, an audible alarm will sound and emit a long beep. Turn off the UPS and unplug at least one connected device. Unplug the power cord from the UPS and press the circuit breaker.

 

  • Possible cause: The battery is dead.

Solution: Leave the SPS connected for at least 4 h, preferably without a connected charge to prevent a network failure from discharging the battery again and leaving the charges without power.

 

  • Possible cause: The drive is damaged.

Solution: Contact the distributor or seller and failing that, the S.S.T.

Mute the SPS beep.
  • Solution: Press the mute button twice in less than 3 seconds.
  • Press again 2 times in less than 3 seconds to unmute again.
The yellow LED flashes every 10 seconds and the audible alarm sounds.
  • Cause: Indicates that the computer is in battery discharge.
  • Solution: Check if the computer has input power. The equipment will return to its normal state once it recovers the input voltage.
The LED flashes every second and the audible alarm sounds.
  • Cause: Indicates that the battery is at the end of its autonomy.
  • Solution: Check if the computer has input power. In case the equipment does not recover input voltage, it will reach the end of its autonomy and will turn off.
The red LED flashes every half a second and the audible alarm sounds.
  • Cause: Indicates that the computer is overloaded
  • Solution: Check the consumption connected to the output of the equipment and reduce it by disconnecting loads. Once the output consumption drops, the equipment will return to its normal state.
The red LED is permanently active and the audible alarm sounds continuously.
  • Cause: Indicates that the equipment is in failure.
  • Solution: Perform a UPS reset. In case the fault does not disappear, contact the distributor or the seller and failing that, the S.S.T.
Meaning of LEDs with a battery symbol and bars at the bottom.

Solution: Indicate the battery charge level, 25% - 50% - 75% - 100%.

 width=

The autonomy time of the SPS is not as expected.
  • Possible cause: The battery is not fully charged.

Solution: Connect the UPS to a mains voltage socket and leave it charging for a minimum of 8 h.

 

  • Possible CauseThe battery is slightly damaged.

Solution: Contact the distributor or seller and failing that, the S.S.T.

 

  • Possible cause: The charges are connected to the sockets without voltage supply through the battery.

Solution: Check that the charges are connected to the sockets that have autonomy through the battery, indicated on the equipment with a symbol of a battery.

Battery replacement procedure.
  • Solution: The battery of the equipment can be changed autonomously. See point 6.2.1. of the user manual.>/li>
The Power Master software is down.
  • Possible Cause: The serial/USB port cable is not connected.

Solution: Connect the serial/USB port cable between the SPS and computer. Use the cable supplied with the unit.

 

  • Possible cause: The USB cable is plugged into the wrong SPS port.

Solution: The USB cable must be plugged into the USB COMM port on the side of the computer

 

  • Possible cause: The SPS HOME+ does not provide battery power.

Solution: Turn off the PC and UPS. Wait 10 seconds and start the SPS HOME+ again. Restarting the drive should resolve the anomaly.

Barcelona Web Design: MontawebMONTAWEB.com
Welcome to Salicru. Select country/language
Australia   English
Bangladesh   English
Camboya   English
China   English
India   English
Indonesia   English
Japan   English
Kazakhstan   English
Laos   English
Malaysia   English
Myanmar   English
New Zealand   English
Pakistan   English
Philippines   English
Singapore   English
South Korea   English
Sri Lanka   English
Taiwan   English
Thailand   English
Vietnam   English
extralarge
large
tablet
mobile
We use proprietary and third-party cookies to keep track of how our website is used and to be able to improve it, adapt the content to your tastes and personalise our advertising, marketing and social media posts. Click on the corresponding buttons to accept all of them, reject them or configure your settings. Please see our Cookie Policy for more information.