EMi3 M 25-2
Servomotor voltage stabiliser single-phase from 25 kVA
Constant stabilisation and savings in overvoltages
Regulation margin:
±15%(2)
Output voltage (V):
220 / 230 / 240 V
System power (VA/W):
25000 / 25000
Code: 6A5DA000006
EAN: 8436035929818
Specifications
Technical specifications
INPUT / OUTPUT
Input / Output
Monofásico
INPUT
Voltage
220 / 230 / 240 V
Regulation range
±15%(2)
Rated frequency
50 / 60 Hz
Frequency range
47.5 ÷ 63 Hz
OUTPUT
Voltage
220 / 230 / 240 V
Accuracy
± 3% (adjustable between 1% ÷ 5%)
Output voltage setting
± 10%
Power (VA/W)
25000 / 25000
Total harmonic distortion (THDv)
<0.2%
Frequency
48 ÷ 63 Hz
Regulation speed
Up to 70 V/s
Performance
Between 96.5% and 97.5%
Voltage disconnection value
Adjustable (3)
Phase unbalancing
0 ÷ 100%
Admissible overloads
Up to 200% for 20 s
Power factor influence
Independent
COMMUNICATION
Ports
2 Dry contacts / RS-232 (4)
Intelligent slot
One (4)
INDICATIONS
Type
LCD display (2x16 characters) + 4 status LEDs
GENERAL
Ambient temperature
-10º C ÷ +55º C(2)
Relative humidity
Up to 95%, non-condensing
Maxium operating altitude
2,400 m.a.s.l.
Degree of protection
IP20
Cooling
Natural or forced depending on power rate(5)
Acoustic noise at 1 metre
<45 dB(A)(6)
Mean time between failures (MTBF)
60,000 hours
Mean time to repair (MTTR)
30 minutes
STANDARDS
Safety
IEC/EN 61558-2-14
Electromagnetic compatibility (EMC)
IEC/EN 62041
Corporate cerification
ISO 9001, ISO 14001, ISO 45001
DIMENSIONS
Depth (mm)
895
Width (mm)
460
Height (mm)
705
WEIGHT
Weight (kg)
119
(1) Ask for other settings
(2) Other ranges available on request
(3) With optional voltage maximum-minimum
(4) Mutually exclusive ports
(5) Forced from 20 kVA for single phase and 55 kVA for three-phase
(6) <65 dB(A) for models with forced ventilation
Video
View distributor
Select Region and Country/Province to view Distributors
Services
Commissioning
Puesta en Marcha 7.5 - 25 kVA UPS & Stabilisers
Commissioning for Uninterruptible Power Supply (UPS) systems and voltage stabilizers with power between 7.5 and 25 kVA inclusive. During established working hours.
Code: 502AA000054
Puesta en Marcha fuera de horario laboral <=35 kVA
Salicru out-of-hours commissioning service for UPS and stabilisers up to 35 kVA
Code: 502AA000067
Maintenance contracts
Additional Preventive Visit VP+ 4-30 kVA
Additional preventive visit included during warranty or maintenance contract for UPS and Stabilisers with power between 4-30 kVA (for any maintenance contract modality)
Code: 555AB002222
Maintenance Contract 00 1Y
Annual maintenance contract with preventive and corrective visits. Batteries, materials, and consumables not included. During established working hours.
Code: 555AB999997
Maintenance Contract F0 1Y
Annual maintenance contract with preventive and corrective visits, materials, and consumables. Batteries not included. During established working hours.
Code: 555AB999995
Maintenance Contract M0 1Y
Annual maintenance contract with preventive and corrective visits and materials. Batteries and consumables not included. During established working hours.
Code: 555AB999996
Maintenance Contract VP 1Y
Annual maintenance contract with preventive visit. Corrective visits, batteries, materials, and consumables not included. During established working hours.
Code: 555AB999999
Technical Support 24/7
Continuous technical assistance available 24 hours a day, 7 days a week, ensuring rapid help whenever needed (for any maintenance contract modality)
Code: 555AB002219
Telephone Support 24/7
24/7 telephone support providing immediate assistance, technical advice, and help with any issues at any time, day or night. (for any maintenance contract modality)
Code: 555AB002220
Accessories
Communications
NIMBUS ROUTER 4G
Device that uses 4G mobile networks to provide Internet connection via WiFi or Ethernet.
Code: 663AA002241
EAN: 8436584876281
NIMBUS SNMP Card
Nimbus Ethernet adapter / SNMP web adapter. Connection to the Salicru cloud (IoT - MQTT). Modbus TCP and RS232 protocol. SNMP V2. Shutdown of servers, via RCCMD software.
Code: 663AA002223
EAN: 8436584876274
Generic
BE-EMi3-M-25-2/2
External Manual Bypass for 25 kVA single-phase EMi3 series equipment allows maintenance to be carried out without interrupting the power supply to the protected equipment.
Code: 6A5OP000020
Downloads
Documents
Data sheet
Manuals
Certificates & Declarations
Request information about EMi3 M 25-2
Welcome to Salicru. Select country/language
Argentina Español
Bolivia Español
Brazil Português
Caribbean Islands English
Chile Español
Colombia Español
Costa Rica Español
Cuba Español
Dominican Republic Español
Ecuador Español
El Salvador Español
Guatemala Español
Mexico Español
Nicaragua Español
Panama Español
Paraguay Español
Peru Español
United States English
Uruguay Español
Venezuela Español
extralarge
large
tablet
mobile
We use proprietary and third-party cookies to keep track of how our website is used and to be able to improve it,
adapt the content to your tastes and personalise our advertising, marketing and social media posts.
Click on the corresponding buttons to accept all of them, reject them or configure your settings.
Please see our Cookie Policy for more information.




MONTAWEB.com